MI150_MI300_MI500.book Seite 24 Freitag, 17. November 2006 3:36 15
Cleaning and caring for the inverter
8
Cleaning and caring for the inverter
Caution
Do not use any sharp or hard objects for cleaning since they may
damage the device.
➤ Occasionally clean the device with a damp cloth.
9
Rectifying faults
Fault
No output voltage
No output voltage
No output voltage
No output voltage
The device switches on and
off repeatedly
The inverter switches off
when the consumer is
switched on
The output voltage is too
low.
24
Cause
No contact to the battery
Overheating
Defective fuse (in the inverter
or the vehicle)
Device defective
Excessive constant load
Starting current too high
Batter voltage below 10.5 V
(MI150-012/MI300-012/
MI500-012) or 21 V
(MI150-024/MI300-024/
MI500-024)
MI150, MI300, MI500
Remedy
Check contact and cable.
Switch on the ignition if
necessary.
MI150: Check the 12/24 V
socket and replace it if
necessary.
Switch off power consuming
devices.
Let the inverter cool down
and ensure better ventilation.
Replace the the fuse with one
of the same specifications.
Replace the device.
Reduce the load.
Compare the device power
with the maximum power of
the inverter.
Charge the battery (start the
engine).