ELECTRICAL CONNECTION 090PE4 - 190PE4
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
400V/3N (230V/3 available on request) (see
attached wiring diagrams). Specify the cor-
rect voltage for your device; it cannot be
modified after purchase.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safe-
ty breaker close to the appliance.
IT
GB
DE
FR
ES
English
B
A
2 - Pull off the knob (B).
3 - Undo the screws (C) and remove the control
panel (D).
4 - Connect the circuit-breaker (A) to the terminal
board (E) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual. Use a flexible cable
with at least type H07RN-F characteristics, rat-
ed for an operating temperature of at least
80°C.
Important
When connecting, take care to connect the
neutral and earth lines.
5 - Replace the control panel (D) and the knobs (B)
on completion of the operation.
C
C
D
- 18 -
E
IDM-39615102000.tif