Descargar Imprimir esta página

Hatco HBG Serie Manual De Instalación Y Operación página 9

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
NOTICE
Do not modify wiring or cut thermostat capillary wire on
control box to increase remote mounting distance. Cutting
thermostat capillary wire will cause unit to overheat and
may damage unit as well as surrounding countertop.
NOTE: The remote control box should be mounted using
screws with a 1/4" (6 mm) minimum diameter screw
head inserted through the keyholes located on the
mounting brackets. The remote control box is to be
readily removable, not permanently mounted.
8. Once all components are secured, proceed to the
OPERATION section.
NOTE: A 1829 mm (6') cord is supplied with this appliance;
any excess cord should be neatly routed so it does not
hang down.
Model
HBGB-2418
HBGB-3018
HBGB-3618
HBGB-4818
1235 mm (48-5/8") – 1241 mm (48-7/8")
HBGB-6018
1540 mm (60-5/8") – 1546 mm (60-7/8")
HBGB-7218
1845 mm (72-5/8") – 1851 mm (72-7/8")
Form No. HBGCEM-0520
Countertop Cutout
Width
625 mm (24-5/8") – 632 mm (24-7/8")
778 mm (30-5/8") – 784 mm (30-7/8")
930 mm (36-5/8") – 937 mm (36-7/8")
Trim Mounting Ring
Metallic
Countertop
HBGB Countertop Installation
Depth
473 mm (18-5/8") – 480 mm (18-7/8")
473 mm (18-5/8") – 480 mm (18-7/8")
473 mm (18-5/8") – 480 mm (18-7/8")
473 mm (18-5/8") – 480 mm (18-7/8")
473 mm (18-5/8") – 480 mm (18-7/8")
473 mm (18-5/8") – 480 mm (18-7/8")
Apply a bead of NSF-approved
sealant between the metallic
countertop and trim mounting ring.
Sealant must be rated for use at
a minimum temperature of
121°C (250°F).
9
INSTALLATION

Publicidad

loading