Descargar Imprimir esta página

Bosch Stora BP 200-1000 EP Instrucciones De Instalación Y Manejo Para El Técnico página 20

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
Transport
2.9
Tech data
Dimensions and specifications
Memory
Available capacity
Maximum heating water temperature
Maximum operating pressure of heating water
Standby heat loss (24 h) in accordance with DIN 4753 Part 8
1) Excluding distribution losses outside the cylinder.
Table 20 Tech data
2.10
Product data for energy consumption
The following product data complies with the requirements of EU
Regulation No 814/2013 as a supplement to Ecodesign Directive 2017/
1369/EU and Regulations EU 814/2013 as retained into UK law and
amended.
Manufacturers who implement these guidelines and state the ErP values
are permitted to use the "CE" and "UKCA" mark.
The following product data satisfy the requirements of the EU
Regulations No. 812/2013 and No. 814/2013 supplementing EU
Ordinance 2017/1369.
Manufacturers who implement these guidelines and state the ErP values
are permitted to use the "CE" mark.
Product
Product
number
type
volume (V)
8735100973 BP 200 EK 1
B
8735100974 BP 500 EP 1
C
8735100978 BP 1000 E 1
C
Table 21 Product data for energy consumption
3
Transport
WARNING
Risk of injury from carrying heavy loads and inadequately securing
loads for transport!
▶ Use suitable means of transport.
▶ Secure the cylinder to prevent it falling.
▶ Move packed cylinder with a sack truck and lashing strap ( Fig. 7,
page 37).
-or-
▶ Move unpacked cylinder with a transport net, during handling,
protect connections against possible damage.
20
1)
Cylinder
Heat
Energy
retention
efficiency
loss (S)
class for
DHW
treatment
199,4 l
50,7 W
B
480,0 l
100,5 W
C
867,0 l
134,0 W
C
Unit
BP 200 EK
-
l
199
°C
95
bar
3
kWh/24 h
1.22
4
Mounting method
The cylinder is delivered fully assembled.
▶ Check that the cylinder is complete and undamaged.
4.1
Installation location
NOTICE
Risk of damage from inadequate load-bearing capacity of the
installation surface or unsuitable floor surface!
▶ Ensure that the installation surface is level and offers sufficient load-
bearing capacity.
▶ Install the cylinder in a dry frost-free interior.
▶ If there is any danger of water accumulating on the floor of the
installation location: place the cylinder on a plinth.
▶ Observe the minimum wall clearances inside the installation room
( Fig. 8, page 37).
4.2
Fitting temperature sensors
Assembly is also possible once the insulation has been installed.
▶ Observe the technical guide when positioning the sensor.
▶ Apply heat conducting paste to the contact surfaces.
▶ Push the temperature sensor into the sensor pocket up to the catch.
▶ Mark the temperature sensor leads according to how the sensor is
being used; do this at the end of each lead.
▶ Route the sensor lead to the control unit, ensuring it will be possible
to install the insulation.
▶ Establish the electrical connection to the sensor leads. In doing so
observe the installation instructions for the control unit.
4.3
Setting up the cylinder
NOTICE
Material damage due to excessively low ambient temperature.
If the ambient temperature is below 15 °C, the foil jacket tears while
closing the zipper.
▶ Heat the foil jacket (in a warmed-up room) to above 15 °C.
BP 500 EP
 Fig. 4 - 6, page 35 - 36
480
95
6
2.41
Stora – 6721835329 (2023/06)
BP 1000 E
867
95
3
3.22

Publicidad

loading