Phase unbalance (for threephase motors only)
Higher values could be caused by the motor and/or the electricity main. Check the power draw in the other two
motor-main combinations, making sure that the same rotation direction is maintained.
The optimum connection is that with the least difference in power draw between the phases. Note that if the
higher power draw is always on the same line phase, the main cause of unbalance will be due to the power
main.
6
Use and management:
6.1 Starting:
If the starting unit is unable to start (no "take-off"), do not insist as this could only damage the component. Identify the malfunction and repair.
If an indirect starting system is used, the starting transient must be brief and must never last more than a few seconds.
General prescriptions for the use of the INVERTER
- During commissioning and/or use, the minimum frequency must not be lower than 30 Hz, with a steady voltage to frequency ratio
- Maximum acceleration ramp time - 3 seconds
- Maximum deceleration time equal to twice the maximum acceleration time.
Ensure the following operating conditions:
750
Voltage gradient
Conditions that must be met regardless of the length of the power cables.
General prescriptions for the use of the SOFT STARTER:
- The SOFT STARTER device must carry out a voltage ramp starting or a constant current starting
- The SOFT STARTER device must not carry out a current ramp starting or a torque ramp starting
- Maximum acceleration ramp time - 3 seconds
- Maximum deceleration time equal to twice the maximum acceleration time
- Deceleration method either by freewheel or by voltage ramp, not by braking
- Always make sure that the soft-starter is off once the assembly start phase has completed.
assembly by connecting it directly to the grid (or with another device).
6.2 Running and inspections:
ATTENTION
Once installed, the electric pump will require no particular maintenance. To ensure continuously regular operation it is, however,
necessary to periodically check that the pump hydraulics are not clogged by solids and/or thready substances in the pumped liquid.
Also conduct regular preventive maintenance inspections at least once every 5000-10000 hours service, according to whether duty
- the condition of the hydraulic components (consult the "Maintenance" paragraph).
causes and proceed with repairs, as indicated in this manual.
6.3
Maintenance:
the right tools. These technicians must have become fully familiar with the contents of this manual and with any other documentation
supplied with the product.
Extraordinary maintenance must only be carried out by authorized specialized workshops.
- never work without a safety harness or on your own. Always make sure you are assisted by a second worker outside, who is able to
promptly act and in safety.
ATTENTION
(CEI 61-50) regulations.
"Dimensions, weights and technical data" paragraph.
Only ever use genuine Caprari spare parts. Failure to do this could void the guarantee and would relieve the manufacturer of all responsibility in
merit.
3 - the denomination and reference number of the part as indicated in the spares catalogue (available from authorized after-sales centers) or shown
Caprari S.p.A.
KICK BACK
1000 V
. e V p
D - M / DS - MS
connection type M to EN 60335-1