Pulley Alignment - Porter Cable PXCMLC3706056 Manual De Instrucciones

Compresores eléctricos de aire, de una sola etapa y accionamiento por correa
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PULLEY ALIGNMENT

To check pulley alignment, remove the belt guard and place a straightedge
(see A) against the pump flywheel (see B) (See Fig. 9). Measure and record the
distance from the straightedge to the edge of the drive belt at point C. Then
measure the distance from the straightedge to the edge of the drive belt again
at points D and E. Both distances should be the same as at point C. If D or E
are different from C, there is a misalignment which must be corrected before
the compressor is run. To correct a pulley misalignment, use the following
procedure.
1.
Remove the belt guard.
2.
Loosen the motor mounting bolts.
3.
Loosen the setscrew on the motor pulley.
Align the motor pulley with the pump flywheel (C = D = E).
4.
5.
Retighten the motor pulley setscrew.
6.
Adjust the proper belt tension.
7.
Retighten the motor mounting bolts.
8.
Reinstall the belt guard. All moving parts must be guarded.
MAINTENANCE
17 - ENG
Fig. 9

Publicidad

Tabla de contenido
loading