• For stubborn limescale, we recommend descaling the appliance by run-
ning the cleaning mode (21) several times in a row. Leave the descaling
agent in the water tray for a maximum of 20 minutes and pour it out after-
wards as described below.
• Important: Pour the descaling agent out over the left front corner of the
appliance (see the arrow on the appliance). No water may enter the air
outlet opening (26). This will damage the appliance and will void any claim
to the warranty.
• To rinse, now fill the cup with 200 ml of tap water and carefully pour the
liquid into the water tray (9) by holding the cup directly over the water tray
(see page 5). Do not pour the liquid into the water tray from high above
the tray! Pour the water out over the left front corner of the appliance.
Repeat the process until there is no more descaling agent in the water
tray (9). Place the Water Cube (24), cover (18), mist chamber (23), water
tank (6) and fragrance container (20) back into the appliance. If the water
tank is not sitting right, check if the upper part of the mist chamber (23)
is properly mounted.
• Regularly as required: For external cleaning, rub with a damp cloth and
then dry thoroughly.
• At the end of the season: Before putting away the appliance at the end
of the season, run the cleaning mode as described above. Then clean it
thoroughly inside and out and let it dry completely. Insert a new Water
Cube (24) in order for your appliance to be ready for the start of the next
season.
Replacement of the anticalc cartridge
• Please find the recommended replacement interval in the table (see "Be-
fore setup").
• Tip: the efficiency of the cartridge (8) can be inspected with a simple test.
Hold a small mirror in the mist (27) for a few seconds. If white deposits
(calcium carbonate) appear on the mirror, then the cartridge needs chang-
ing.
• The anticalc cartridge is located on the inner side of the tank lid (7). First,
screw the tank lid (7) off the water tank (6) and then screw the cartridge
off the tank lid. Dispose of the cartridge in the domestic waste (8). Prior to
screwing the new anticalc cartridge into the inside of the tank lid, soak it
in water (not in the water tank!) for 24 hours.
• Keep the tank lid (7) when replacing the cartridge!
Water Cube™ – optimal hygiene for your air humidifier
The Water Cube™ (24) by Stadler Form provides optimal hygiene in your air
humidifier. It keeps your humidifier running smoothly, extending its lifespan.
The Water Cube even works when your appliance is switched off, so the
humidifier stays fresh all season long. We recommend replacing the Water
Cube at the start of the humidifier season.
Repairs
• Repairs to electrical appliances must only be carried out by a qualified
electrical technician. If improper repairs are carried out, the warranty
lapses and all liability is refused.
• Never operate the appliance if the adaptor or plug is damaged, after it has
malfunctioned, if it has been dropped or has been damaged in any other

Publicidad