Descargar Imprimir esta página

SICK MAS Serie Instrucciones De Uso página 28

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
OPERATING INSTRUCTIONS
10.3
Process data structure
en
28
O P E R A T I N G I N S T R U C T I O N S | MAS
IO-Link
Process data
Bit 0...5 / data type
Bit 8 / Description / Data type
Bit 9...10 / Description / Data type
Bit 11 / Description / Data type
Bit 12 / Description / Data type
Bit 13 / Description / Data type
Bit 14 / Description / Data type
Bit 16...31 / Description / Data type
Angle: The angle between the magnet and sensor from 0 to 35,999 digits after setting
the setup offset. The last two digits represent decimal places.
e.g.: 745 = 7.45°
Direction of rotation: The direction of rotation can be set using ISDU 85. This parame‐
ter shows the actual direction of rotation of the magnet compared to the setting on
ISDU85:
0 = Magnet rotates in the opposite direction to the ISDU85 setting.
1 = Magnet rotates in the same direction as the ISDU85 setting.
Rotation index: Feedback regarding a full rotation of the magnet. The duration of the
signal can be set using ISDU 4379:
0 = Magnet has not completed a full revolution since Power ON or the last full revolution.
1 = Magnet has completed a full revolution.
Standstill monitor: The rotational movement of the magnet:
0 = Magnet is moving.
1 = Magnet is stationary
NOTE
A speed under 0.02 rad per second is evaluated as a standstill.
Magnet positioning aid: This parameter can only be used for customer-specific sensors.
Magnet status: Quality of the encoder signal (magnet) in pre-defined 25% window incre‐
ments:
0 = 0...25%
1 = 25...50%
2 = 50...75%
3 = 75...100%
Magnet detection: The detection status of the magnet:
0 = Magnet not detected
MAS...A00
V1.1
4 bytes
Byte 0: bits 31...24 
Byte 1: bits 23...16 
Byte 2: bits 15...8
 Byte 3: bits 0...7
Q
 / Boolean
L1-L6
Magnet Detection / Boolean
Magnet Status / Uint2
Magnet Positioning Aid / Boolean
Rotation Index / Boolean
Standstill Monitor / Boolean
Direction of Rotation / Boolean
Angle / UInt16