OBJ_BUCH-1702-001.book Page 21 Thursday, February 14, 2013 4:05 PM
components must be disposed of in impermeable plastic bags
conforming with the valid regulations for the disposal of such
waste.
For maintenance on behalf of the user, the vacuum cleaner
must be disassembled, cleaned and maintained as far as fea-
sible, without causing a risk for the maintenance personnel or
other persons. Prior to disassembly, the vacuum cleaner
should be cleaned in order to prevent any risks. The room/en-
closure in which the vacuum cleaner is disassembled should
be well ventilated. Wear personal protective equipment dur-
ing maintenance. After the maintenance, the maintenance ar-
ea should be cleaned.
Removing/Replacing the Flat-fold Filter
(see figures J1 –J2)
Replace a damaged flat-fold filter 24 immediately.
– Pull the locking latch 14 and open the filter cover 34.
– Grasp the flat-fold filter 24 by the fins, pull up and remove.
– When taking out the flat-fold filter 24, remove any accumu-
lating dust and debris from the closing edge of the filter
cover 34 using a moist cloth.
– Insert the new flat-fold filter 24; observe proper and tight
seating.
– Shut the filter cover 34 again (must be heard to engage).
Container
– Wipe out the container 1 from time to time with a commer-
cially available, non-scouring cleaning agent and allow to
dry.
Correction of Malfunctions
Problem
The vacuum turbine does not start.
Vacuum turbine switches off.
Vacuum turbine does not restart after emptying
the container.
Vacuuming power decreases.
Dust escapes during vacuuming
The automatic shut-off (wet vacuuming) does
not respond.
Filter cleaning inoperative.
Bosch Power Tools
Level Sensors (see figure K)
Clean the level sensors 35 occasionally.
– Unlock the latches 9 and remove the vacuum lid 8.
– Clean the level sensors 35 with a soft cloth.
– Reattach the vacuum lid 8 again and lock the latches 9.
Storage and Transport (see figure L)
– Wind the mains cable around the cable holder 13.
– Insert the accessories into the holders provided: Vacuum
tubes 29 in holders 15, crevice nozzle 25 in holder 16,
floor nozzle 28 in holder 17.
– Undue the elastic tie-downs of the vacuum-hose holders 4
and place the vacuum hose 21 around the vacuum cleaner
lid into the holders 4.
Reattach the elastic tie-downs.
– Mount the L-Boxx onto the retainers 7.
– To prevent back injuries, remove a full disposal bag or dust
bag, or drain vacuumed-up fluids before transporting the
vacuum cleaner.
Carry the vacuum cleaner only by the carrying handle 6.
– Store the vacuum cleaner in a dry room and secure it
against unauthorised use.
– To lock the castors 12, actuate the castor brakes 11 by
pushing down.
Corrective Measure
– Check mains cable, mains plug, fuse, socket outlet and filling-level sensors
35.
Mode selector switch 5 set to "Start/Stop automatic".
– Set mode selector switch 5 to the "vacuum" symbol and switch the power
tool connected to the socket outlet 3 on.
– Empty container 1.
– Switch vacuum cleaner off and wait 5 seconds; switch on again after 5 sec-
onds.
– Clean level indicators 35 as well as the space between the level indicators 35
with a brush.
– Remove clogs from vacuum nozzle, vacuum tubes 29, vacuum hose 21 or
flat-fold filter 24.
– Replace disposal bag 23 or dust bag.
– Engage filter cover 34 properly.
– Mount vacuum cleaner lid 8 properly and lock latches 9.
– Replace flat-fold filter 24.
– Check proper installation of the flat-fold filter 24.
– Replace flat-fold filter 24.
– Clean level indicators 35 as well as the space between the level indicators 35
with a brush.
The automatic shut-off does not function with non-conductive liquids or
foam/bubbles.
– Monitor the level continuously.
– Push the SFC+ switch 18 toward the rear (position 1).
English | 21
1 619 929 L27 | (14.2.13)