ASSEMBLING THE DOSATRON (cont...)
NOTE : the maximum suction height is 4 meters (13 vertical feet).
- Fit the hose equipped with its strainer, and immerse it in the solution to
be injected.
- screw the bypass button (model D20s) to median position (refer to §
"Using for the first time").
IMPORTANT ! - Do not put the suction tube strainer on the bottom of
the stock solution container. The strainer must be suspended at least 10
cm [4"] above the bottom of the tank to avoid sucking up the insoluble
particles that may damage the injection assembly (Fig. 5).
- Do not put the strainer on the ground.
WHAT yOU SHOULD DO
WHAT yOU MUST NOT DO
Fig. 5
Under no circumstance should the solution level be above the water
inlet of the Dosatron (to avoid siphoning situations).
©