8. Securely connect the negative (−) black clamp to a non-moving, metal part of the engine or
frame as far away from the vehicle battery as possible.
9. Turn jumpstarter power switch to the
10. When the clamps are properly connected to the battery, the status light will illuminate a steady
red. It may take a few seconds after connection for the red light to illuminate. When the
light illuminates steady red, it is safe to proceed in these instructions. If the status light fails to
illuminate steady red, consult the troubleshooting section of this manual.
11. Place unit on a secure surface away from moving parts.
12. Start vehicle engine. Stop if the vehicle does not start after 3 to 4 seconds of engine cranking.
Wait 3 to 4 minutes, then try again. If engine does not start after second attempt, discontinue
cranking and consult a professional.
13. The internal safety timer will automatically disconnect the circuit after 1 minute to prevent the
vehicle battery from reverse charging the unit. If your vehicle still has not started, disconnect
the cables and try the procedure again.
14. When finished, switch the jumpstart power switch to the " " position. Disconnect the clamps
in reverse sequence of connecting procedure—first disconnect negative (black), then positive
(red) clamps. Do not let the clamps touch each other.
15. When convenient, using either AC or DC charging adapter, completely charge the
iOnBoost battery.
16. Store the unit and charge adapters in a cool, dry environment, away from flammable
materials. Remember to fully charge the unit every three months.
Bypass Mode:
It is possible to override the safety circuit in the iOnBoost V10 if your battery voltage is over 11V or
below 2V.
Caution: Extreme caution should be taken when using this mode. Bypassing the safety circuit
exposes the user and the unit to potentially hazardous conditions that could result in sparks, fire or
even bodily harm if proper precautions aren't taken.
1. Disconnect cables
2. Turn on the jumpstart switch
3. Press and hold the override button above the switch. Hold for about 3 seconds and then you
will hear a click and see the light come on.
4. Connect the cables taking extra caution to connect the cables with the right polarity
5. Start the car. The internal safety timer will automatically disconnect the circuit after 1 minute. If
your vehicle still has not started, disconnect the cables and try the procedure again.
TROUBLESHOOTING
Jumpstart Warning Lights
The iOnBoost is ready to jumpstart when the jumpstart power switch is on and a steady red status
light illuminates. The following chart displays the combinations of warning lights that occur when the
iOnBoost fails to display the ready light:
10
®
position.
www.wagan.com