SIMPLIFIED LEARNING PROCEDURE
For better adjustment of the obstruction control, it may be necessary (mainly with the trimmer "FOR" set at the
!
maximum or with heavy doors), to intervene during the opening and closing phases (points 7 - 8 - 10) by pressing the
activation key of the transmitter or the push button P1/SET on the control unit as soon as the driving carriage comes
into contact with the mechanical stop.
1. Put the door in an
intermediate position.
INITIAL SETTINGS OF DIP-SWITCHES
Dip
Status
OFF
01
ON
OFF - OFF
OFF - ON
02 - 03
ON - OFF
ON - ON
OFF
04
ON
TRIMMER
A variation of the trimmer "FOR" (speed) requires the reset learning procedu-
re to be repeated (point 2) since the manoeuvre times vary. Decelerations
are automatically defined in the last 10% of the manoeuvre.
MAX
MAX
MAX
END of learning
procedure
23
PROGRAM THE TRAVEL LIMITS
2. RESET: press and
hold the programming
Operation
Safety test disabled
Safety test enabled
Dead man's switch mode
Automatic closing mode
Step by step mode (Open - Stop - Close - Stop)
Step by step mode with automatic closing
Flashing light fixed
Flashing light flashing
Obstacle sensitivity (OBS):
Regulation of the activation time
from 0.1 to 3 seconds.
Pause time (PAU):
Regulation of the pause time from
0 to 60 seconds.
Power / Speed (POW):
Regulation from 50% to 100% of
the power.
10. The door close
until mechanical stop
Yellow LED switches off
button P1/SET
for 2 sec.
ON
1 2 3 4
3. Yellow led
flashes
4. Within 5 seconds,
press the programming
button P1/SET
for 1 sec.
5. Yellow LED
stays on
6. The control unit
briefly open
7. The door close until
mechanical stop
8. The control unit
briefly open
9. Pause for one
second