Descargar Imprimir esta página

Default Setting - BFT SP 3500 Instrucciones De Uso

Accionador para cancelas correderas de cremallera

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
Logic
Definition
Pre-alarm
PRE-ALARM
Deadman
HOLD-TO-RUN
Block pulses during
IBL OPEN
opening
Block pulses during
*IBL TCA
TCA
Block pulses during
IBL CLOSE
closing
Open in other
OPEN IN OTHER
direction
DIRECT.
Configuration of
safety input SAFE 1.
SAFE 1
72
Configuration of
safety input SAFE 2.
SAFE 2
74
Configuration of
safety input SAFE 3.
SAFE 3
77
Configuration of
command input IC 1.
IC 1
61
Configuration of
command input IC 2.
IC 2
62
Configuration of
command input IC 3.
IC 3
64
Configuration of
command input IC 4.
IC 4
65
Configuration of
AUX 3 output.
AUX 3
26-37
Protection
Setting the
protection level
level
INSTALLATION MANUAL
Cross
out
Default
setting
used
0
The flashing light comes on at the same time as the motor(s) start.
0
 
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse operation.
Deadman mode.
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
wARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
0
 
2
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
wARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Pulse operation during opening.
Deadman mode during closing.
Input 64 is configured as PULSE OPEN.
3
Input 65 is configured as CLOSE UP.
wARNING: safety devices are not enabled during closing.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
0
Standard operating mode
0
 
1
Opens in other direction to standard operating mode
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
0
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
 
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
2
 
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
0
Input configured as Start E.
0
1
Input configured as Start I.
2
Input configured as Open.
4
3
Input configured as Close.
 
4
Input configured as Ped.
2
5
Input configured as Timer.
3
6
Input configured as Timer Pedestrian.
0
Output configured as 2nd Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light
5
Output configured as Alarm
0
6
Output configured as Flashing light
7
Output configured as Latch
8
Output configured as Magnetic lock
9
Output configured as Maintenance
10
Output configured as Flashing Light and Maintenance.
A - The password is not required to access the programming menus
0
E - The board's parameters can be edited via the U-link network
1
Not used
2
Not used
0
3
Not used
A - You are prompted to enter the password to access the programming menus
4
The default password is 1234.
E - The option of editing the board's parameters via the U-link network is disabled.
Optional extras
21
SP 3500 -

Publicidad

loading