Descargar Imprimir esta página

BFT SP 3500 Instrucciones De Uso página 22

Accionador para cancelas correderas de cremallera

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
Logic
Definition
Serial mode
(Identifies how board
SERIAL MODE
is configured in a BFT
network connection).
Address
ADDRESS
Configuration of
EXPI1 input on
input-output expan-
EXPI1
sion board.
Configuration of
EXPI2 input
on input-output
EXPI2
expansion board.
Configuration of
EXPO2 output
on input-output
EXPO1
expansion board
Configuration of
EXPO2 output
on input-output
EXPO2
expansion board
TRAFFIC LIGHT
Traffic light pre-
flashing
PREFLASHING
TRAFFIC LIGHT
Steadily lit red light
RED LAMP
ALWAYS ON
22 -
SP 3500
INSTALLATION MANUAL
Cross
out
Default
setting
used
0
1
2
3
[ ___ ]
0
0
1
2
3
4
5
6
7
8
9
10
1
1-2
11
12
13
14
0
1
2
3
4
0
5
6
1-3
7
8
9
10
1
2
1
3
4
4-5
5
6
7
9
8
9
6-7
10
0
0
 
1
0
0
 
1
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other
boards.
SLAVE opposite leaves in local network : the control unit is the slave in an opposite leaves network
with no smart module (fig.R)
MASTER opposite leaves in local network: the control unit is the master in an opposite leaves net-
work with no smart module (fig.R)
Identifies board address from 0 to
119
(see U-LINK OPTIONAL MODULES section)
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as Phot test safety (tested photocell).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot op test safety (tested photocell active during opening only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot cl test safety (tested photocell active during closing only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Input configured as Bar safety (tested safety edge).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light.
Output configured as Alarm.
Output configured as Flashing light.
Output configured as Latch.
Output configured as Magnetic lock.
Output configured as Maintenance.
Output configured as Flashing Light and Maintenance.
Pre-flashing switched off.
Red lights flash, for 3 seconds, at start of operation.
Red lights off when gate closed.
Red lights on when gate closed.
Optional extras
in a local BFT network connection.

Publicidad

loading