6 - Troubleshooting
Problem
The screwing by push
pull is not working
correctly
The setting cycle is not
proceeding
The quality of the
setting is not correct
The automatic
unscrewing is not
proceeding
The display screen
doesn't turn on
48
Possible causes
The Push pull sensor has to be calibrated
Damaged mandrel thread
Problem in the motor
The setting conditions are not fullfilled
The RIVKLE
thread is damaged
®
after setting
The bulge of the RIVKLE
is not
®
well formed
The RIVKLE
head is not in contact
®
against the support after setting
The RIVKLE
turns on the support
®
The hydraulic pressure has not been
reached.
RIVKLE
tapping or threading of the
®
damaged draw mandrel.
Problem in the motor
The battery is discharged
The tool remains unused for several hours
Solution
Switch off the battery and install it again
Replace the mandrel following the
instructions
Check the motor idle rotation by pressing
the Reset button
• Ensure that the Push pull screwing has
been done
• Change the condition for allowing the
setting launch
• Adjust the position of the anvil following
the instructions.
• Excessive setting force. Check the
setting force value range in the
catalogue of the RIVKLE
®
• Damaged mandrel thread. Replace
the mandrel following the instructions.
• Thickness incompatible with the
RIVKLE
®
• The hydraulic pressure has not been
reached. Fill oil, following the instructions
Make sure the RIVKLE
is push against
®
the support while setting
• Setting force is too low. Check the
setting force value range in the
catalogue of the RIVKLE
®
• Repeat the setting test following the
instructions.
Fill oil, following the instructions
Replace the mandrel following the
instructions
Check the motor idle rotation by pressing
the Reset button
Replace the battery with a charged one
Remove the battery and reload it