CAUTION:
• The appliance's efficiency can be reduced if the pre-filter is not cleaned regularly.
•
Never use a pre-filter that is still damp.
•
The pre-filter is the only filter which can be re-used and washed with water. The particle, NanoCaptur
and active carbon filters cannot be cleaned and re-used. Never wash with water.
•
To replace the filters, follow the instructions in the section « Disassembling/Reassembling filters ».
Your replacement filters are available under the following codes:
Filtre
Allergy+ filter
Active carbon filter
NanoCaptur+ filter
IMPORTANT: Resetting the filters
The reset light flashes when a filter needs to be replaced or cleaned (Prefilter). Once the filter has
been replaced, hold down the reset button for 3 seconds.
Forced reset:
If you have replaced a filter before its end of life, force the reset of the filter replacement cycle:
1. Hold the reset button for 3 seconds.
2. Press the reset button briefly to select the filter you have changed.
3. After selecting the filter to reset, hold the reset button for 3 seconds. The new filter life is then
reset.
4. If the reset filter button is not is activated for 10 seconds in forced reset mode, the reset mode
is canceled.
« TIPS FOR CHANGING FILTERS »
• Avoid handling used filters if you suffer from allergies or asthma.
• Wear gloves when changing the filters, or wash your hands well afterwards.
• Put used filters directly into a closed, air-tight bag before throwing them away to
avoid spreading pollutants.
POLLUTION SENSORS
The particles sensor and gas sensor (model PU608x only) need to be cleaned regularly (every 2
months) and appropriately.
Make sure you turn off and unplug the appliance before cleaning the pollution sensors and follow the
recommendations below:
1. Clean the air inlet and outlet using a soft brush or cloth.
2. Open the sensor cover located on the right-hand side of the appliance.
3. Lightly wet a cotton swab and remove any dust from the lens and the inlet/outlet. Wipe using
a dry cotton swab.
4. Clean the gas sensor using a soft brush or vacuum cleaner.
2
1
20
Code PU608x
XD6077
XD6061
XD6083
.
.
3
4
IMPORTANT:
• Never use a detergent or metal object to clean the sensors.
• The efficiency of the sensors may be reduced if not cleaned regularly.
• Cleaning frequency varies depending on the operating environment of the appliance. If it is
used in a dusty environment, clean the sensors more frequently.
STORAGE
When you are not using the appliance, store it in a cool, dry place.
IN THE EVENT OF A PROBLEM
• Never dismantle your appliance yourself. A poorly repaired appliance can cause risks for the user.
• Check the troubleshooting table below before contacting an approved Service Center:
Problem
Check
Is the power cord connected?
Are all the display elements off?
The appliance will not
switch on.
Is there a power outage?
Is the front door closed?
The air flow does not
Is the appliance in silent or
change automatically.
boost mode?
The flow is a lot weaker
Does the filter need to be
than before.
cleaned or replaced?
There is an unpleasant
Does the filter need to be
smell coming from the
cleaned or replaced?
air outlet.
Is the sensor lens covered with
dust?
The air quality light
Does the light still indicate poor
does not change color.
air quality?
Does the light still indicate ex-
cellent air quality?
WARRANTY
Contact an approved Service Center if:
• your appliance has been dropped
• your appliance or its power cord is damaged
• your appliance is not working properly
LET'S HELP PROTECT THE ENVIRONMENT!
Your appliance contains valuable materials which can be recovered or recycled.
Leave it at a local waste collection point or take to an approved service center so that it
can be processed.
EN
Solution
Connect the power cord to a plug
with the correct voltage.
Press the start button and select the
required function.
You can use your purifier once the
power turns on again.
Close the front door properly.
Select the correct operating mode
AutoDay or Auto Night.
Check the filter cleaning and replace-
ment frequencies and clean/replace
the filter(s) if necessary.
Check the filter cleaning and replace-
ment frequencies and clean/replace
the filter(s) if necessary.
Clean the sensor lens.
Set the sensor sensitivity to «low» or
«medium».
Set the sensor sensitivity to "high"
or "medium".
21