The installation and testing operations must be performed solely by qualified personnel in
order to guarantee the proper and safe operation of the automatic gate.
•
The company declines any responsibility for damage caused by incorrect installations due to
incompetence and/or negligence.
•
Before assembling the automatism, check that the gate is in perfect working order, hangs well
on its hinges and is suitably lubricated. It must also comply with the safety standards in force in the
country of installation..
INSTALLATION
1- Before fastening the brackets provided, establish the coordinates using the data
given in Table 1, bearing in mind that they are valid if the operator is at maximum
extension minus one centimetre of the available stroke (CD) when the gate is
closed to obtain maximum working efficiency.
2- Data B in the table, with reference to the single values A, are to be considered as
values (recommended).
3-To anchor the piston, use the fastening brackets provided.
1- Establish coordinates A + B that are to
be used.
2- Note: The stroke used (Cu) of the
Operator must never be equal or
greater than the available stroke (CD).
3- The sum of coordinates A + B,
establishes the stroke used Cu .
TABLE 1
Opening angle
90° Available stroke = 400mm
(without limitswitch)
Note 1: A+B = Cu (Stroke used)
CONSIDERATIONS FOR INSTALLATION
COORDINATES AND TABLE
CD = (Available stroke) = 400mm
R223
A
B
160
160
175
175
185
185
200
200
CU
320
350
370
400
14