8
ASSEMBLE THE DEVICE TO THE MOUNTNG HOUSING (BACKBOX)
Assemble the front panel with the attached Main Eletrical Unit carefully using the orange (Torx+Pin) screw driver
provided.
D1101V
Turn the safety screws clockwise until they are firmly tightened.
Tighten the safety screws by hand only (less than 5 newton meter [Nm]), otherwise the Main Eletrical
NOT IC E
Unit housing may be damaged.
If any of the black foam rubber gasket under the front panel protrudes, you can carefully press it in with
the triangle tool provided in the small parts bag. Please do not press too hard, so that the gasket is not
pressed too far into the inside of the housing and the unit will have a leak.
9
ACTIVATE THE DEVICE
If the device is to be supplied with power by a mains adapter, plug the power adapter of the device into a wall
socket. If the device is to be powered via PoE, switch on the PoE-Switch/ PoE-Injector which is connected to the
device. If the device is to be powered via DIN-rail power supply, switch on the DIN-rail power supply.
The Diagnostic-LED indicates whether the device is supplied with power. This LED lights up in green color a few
seconds after you have connected the device to the power supply.
If the Diagnostic LED does not light up, please check the power supply. When using a wall-plug power supply
and not PoE please check whether you have connected the positive pole and negative pole to the device
correctly.
The device is ready for operation (booting up process, any software updates, etc.) once it has emitted a short
diagnosis sound from the integrated loudspeaker. This may last for up to 5 minutes.
D1102V
D1101KH
15