QUICK Install Guide 400H PerforMAX FILL VALVE ® VIDEO HOW-TO VIDEO VISIT: FLUIDMASTER.COM 400H PRODUCT PAGE *See back page for important product warnings and warranty information. SPANISH - Page 16 INSTALL WITH CONFIDENCE...
Página 2
GETTING STARTED TOOLS NEEDED PARTS OVERVIEW Bowl Water Level Dial Bucket Sponge Tank Water Level Adjustment Screw Towel Scissors (Optional) Refill Tube Refill Clip TOP DOWN VIEW Bowl Water Level Dial Shank Washer Locknut Tank Water Level Adjustment Screw...
Página 3
STEP 1: PREPARE TANK A: TURN OFF WATER B: DRAIN WATER Flush toilet to drain most of the water from the tank. FLUSH C: USE SPONGE OR TOWEL TO SOAK UP EXCESS WATER IN TANK Sponge Towel...
Página 4
STEP 2: REMOVE OLD FILL VALVE A: REMOVE CONNECTOR Remove water supply connector from bottom of fill valve by twisting connector nut to the left. NOTE: Inspect water supply connector. Replace it if it is worn, or you don’t know how old it Towel is, to prevent flooding and (Optional)
Página 5
STEP 3: ADJUST HEIGHT OF NEW FILL VALVE A: TWIST FILL VALVE TO ADJUST HEIGHT Top of fill valve cap should measure roughly 3" above top of overflow pipe when installed. NOTE: Increasing height allows more water to fill in the tank. HOLD Do Not Move Lock Ring TWIST...
Página 6
STEP 4: INSTALL NEW FILL VALVE ATTACH REFILL CLIP TO OTHER END OF REFILL TUBE IF UNATTACHED, PUSH REFILL TUBE ONTO REFILL PORT INSERT FILL VALVE Position refill tube to face flush valve making sure fill valve parts do not interfere with lever arm.
Página 7
*Hand-tighten only. DO NOT OVERTIGHTEN. TURN ON WATER Check for leaks. (Go to www.Fluidmaster.com/support for leak solutions.) C: WATER LEVEL After the tank stops filling, water level should fill the tank to roughly ½ inch below top of overflow pipe to ensure a proper flush.
Página 8
STEP 6: FINE-TUNE TANK WATER LEVEL A: FLUSH THE TOILET TO CHECK THE TANK WATER LEVEL After the water stops filling the 1/2" tank, the water level should be roughly ½ inch below the top of overflow pipe to ensure a Overflow Pipe proper flush.
Página 9
STEP 7: FINE-TUNE BOWL WATER LEVEL NOTE: The PerforMAX Fill Valve is pre-set to fill the proper bowl water level in most toilets straight out of the box. Setting for Most Toilets FILL BOWL WITH A GALLON OF WATER Wait 1 minute until the bowl water level recedes down and stops.
Página 10
STEP 7: FINE-TUNE BOWL WATER LEVEL ADJUST THE BOWL WATER LEVEL IF TOO HIGH: Turn the dial towards the closed position. CLOSED IF TOO LOW: Turn the dial towards the open position. FULLY OPEN FLUSH TOILET, CHECK BOWL WATER LEVEL Repeat Steps 7D and 7E until water level in bowl matches the line when the fill valve shuts off.
Página 11
A: FLUSH THE TOILET If you’re satisfied with the flush, YOU’RE DONE! YOU DID IT! We knew you could! Share your success story with friends and family! #FixedMyToilet #Fluidmaster Still not working exactly right? See the next page for Troubleshooting.
Página 12
TROUBLESHOOTING IF THE FILL VALVE: • DOES NOT TURN ON • WON’T TURN OFF • WON’T REFILL TANK REMOVE CAP AND CHECK FOR DEBRIS Turn off water supply. Flush toilet. With right hand push float up, grip and hold shaft under float. With left hand twist cap and lever arm counterclockwise to unlock cap.
Página 13
& arm clockwise to locked position. Always use genuine Fluidmaster parts when installing or repairing. Fluidmaster will not be responsible or liable for use of non-Fluidmaster parts during installation or repair. WATER LEVEL IN BOWL IS TOO LOW...
Página 14
TROUBLESHOOTING FOR CANISTER FLUSH VALVES The Fluidmaster refill clip is not required for installation. If you’ve already installed the refill clip onto the refill tube, simply pull it or cut it off. FOR MANSFIELD ® Push refill tube into refill hole at the top of the flush valve cap.
Página 16
*Consulte la última página para obtener información legal importante. VIDEO HERRAMIENTAS NECESARIAS VIDEO DE Balde, Esponja, Toalla, Tijeras (opcional) CÓMO HACERLO VISITE: FLUIDMASTER.COM EMPEZANDO: RESUMEN DE PIEZAS PAGINA DE ESPECIFICACIONES DEL PRODUCTO 400H VISTA DESDE ARRIBA Dial del Nivel del Agua de la Taza Dial del Nivel del...
Página 17
GUÍA DE INSTALACIÓN RÁPIDA PASO 1: PREPARE EL TANQUE (PÁGINA 3) CIERRE EL AGUA. DRENE EL AGUA. Descargue el sanitario para drenar la mayoría del agua del tanque. USE LA ESPONJA O LA TOALLA PARA REMOVER EL EXCESO DE AGUA EN EL TANQUE.
Página 18
APRIETE DEMASIADO. ABRA EL AGUA. Revise por fugas. (Visite a www.Fluidmaster.com/support para soluciones de fugas). NIVEL DEL AGUA. Después que el tanque termine de llenar, el nivel del agua debe llenar el tanque aproximadamente 1/2" más abajo de la parte superior del tubo de desagüe para asegurar una descarga apropiada.
Página 19
DESCARGUE EL SANITARIO. Si está satisfecho con el descargue, ¡TERMINÓ! ¡LO LOGRÓ! ¡Sabíamos que podía! ¡Comparta su historia de éxito con sus amigos y familia! #FixedMyToilet #Fluidmaster ¿TODAVÍA NO FUNCIONA EXACTAMENTE BIEN? CONSULTE LA SIGUIENTE PÁGINA PARA SOLUCIÓN DE PROBLEMAS.
Página 20
SOLUCIÓN DE PROBLEMAS SI LA VÁLVULA DE LLENADO: (PÁGINA 12) • NO SE PRENDE • NO SE APAGA • NO RELLENA EL TANQUE REMUEVA LA TAPA Y REVISE POR MUGRE Cierre el suministro del agua. Descargue el sanitario. Con la mano derecha, apriete y sostenga el vástago debajo del flotador, suba el flotador con su mano derecha.
Página 21
Siempre utilice piezas de genuino Fluidmaster cuando instale o repare. Fluidmaster no se hará responsable por el uso de piezas que no sean Fluidmaster durante la instalación o reparación. EL NIVEL DEL AGUA EN LA TAZA DEL SANITARIO ESTÁ...
Página 22
Para asistencia para la instalación, comuníquese ¿PREGUNTAS con nuestro departamento de servicio técnico. ADICIONALES? EMAIL, CHAT LLAME a nuestro número gratuito. www.fluidmaster.com/support 1-800-631-2011 Horario Disponible: Lunes – Viernes 5:30 AM - 5:00 PM Hora Estándar del Pacífico...
Página 24
SIN ANULAR la GARANTÍA DE FLUIDMASTER, ya que este sistema no daña los componentes. NO apriete demasiado las tuercas o el tanque, ya que la taza se puede agrietar. Siempre use piezas de calidad Fluidmaster al instalar o reparar. Fluidmaster no se hace responsable por el uso de piezas durante la que no sean de Fluidmaster durante la instalación o reparación.