PART #463 REV. 8 1/04
FLUIDMASTER
®
400C FILL VALVE & FLAPPER
INSTALLATION INSTRUCTIONS
TOOLS NEEDED:
DO NOT USE:
1.
2.
SHANK AND
CONE WASHER
(SEE STEP 4)
LOCK NUT
CONE
WASHER
COUPLING
ANGLE
NUT
ADAPTER
3.
4.
DO NOT use
PUSH
plumber's putty
DOWN
to seal these
fittings.
These parts must be
used as illustrated to
insure water-tight
HAND
connection. Use of
TIGHTEN
existing coupling nut
ONLY
or cone washer may
result in water leakage.
7.
Water supply tube or pipe must extend at least
1/2" inside threaded shank of valve (does not
apply to flanged tubing).
8.
9.
10.
®
7
12.
13.
Tilt/Flush Valve
Built-In
Overflows
China Overflows
599
CLAMP
If the angle adapter cannot be used,
you may need the Model 599 Refill
14.
Clamp (not included).
18.
17.
NOTE: SAVE INSTRUCTION SHEET FOR FUTURE REFERENCE.
CRITICAL LEVEL
MARK ("C.L.")
MUST BE
1" ABOVE
OVERFLOW
FILL VALVE
ADJUSTABLE
HEIGHT
LOCK NUT
®
CONE WASHER
COUPLING NUT
SHANK
WASHER
"C.L."
MARK
SHANK
SHANK
WASHER
TANK
BOTTOM
THREADED SHANK
5.
METAL/COPPER
METAL FLANGED
FLARED TUBING
TUBING
LOCK
NUT
CONE
WASHER
COUPLING
NUT
WATER
SHUT-OFF
Use existing
coupling nut
and washer.
CAUTION: DO NOT USE CONE WASHER
WITH PLASTIC SUPPLY LINE.
11.
REFILL TUBE
OVERFLOW
NIPPLE
PIPE
NOTE: Flow from refill tube must be
positioned just above the overflow
pipe.
15.
ARM
TOP
NIPPLE
REFILL
OVERFLOW
TUBE
ANGLE
ADAPTER
TANK
LEVER
FLOAT CUP
PIPE
OVERFLOW
PIPE
LINK
FLUSH
VALVE
VALVE
BODY
WATER LEVEL
ADJUSTMENT
CLIP
SHANK
WASHER
FLAPPER
THREADED
SHANK
PARTS FOR WATER
CONNECTION
(SEE STEP 8)
Diagram 1
MEASURE
HEIGHT ONLY: DO
DO NOT
NOT INSTALL
MOVE
LOCK RING
1"
6.
METAL SPIRAL
VINYL/BRAIDED
TUBING
CONNECTOR
LOCK
LOCK
LOCK
NUT
NUT
NUT
EXISTING
EXISTING
COUPLING
WASHER
CONE
NUT
WASHER
EXISTING
COUPLING
COUPLING
NUT
NUT
WATER
WATER
WATER
SHUT-OFF
SHUT-OFF
SHUT-OFF
Use existing spiral cone washer.
Captive cone washers
Fluidmaster cone washer may not seal
already included. No
completely on spiral type supply line.
additional washers
needed.
CAUTION: Overtightening of LOCK NUT or COUPLING
NUT could result in breakage and potential flooding.
+
ANGLE
ADAPTER
Do not insert refill tube down into over-
flow pipe below water level. This will
siphon water down the overflow pipe,
which causes the valve to turn on and
off as it tries to keep the tank full.
LIFT
ARM
FIRST
16.
WARNING
DO NOT USE IN-TANK DROP-IN TOILET BOWL CLEANERS
CONTAINING BLEACH OR CHLORINE. Use of such products will:
MUST BE
ABOVE
(1) RESULT IN DAMAGE to tank components and MAY CAUSE
FLOODING and PROPERTY DAMAGE and (2) VOID
PIPE
FLUIDMASTER WARRANTY. DO NOT overtighten nuts or
tank/bowl may crack.
Fluidmaster Flush 'n' Sparkle™ Toilet Bowl Cleaning System is recommended for those
choosing to use in-tank bowl cleaners and WILL NOT VOID the FLUIDMASTER
WARRANTY because it will not damage tank components.
WATER
LEVEL
Because drop-in cleaners used in the tank can result in damaged tank
parts (see WARNING above), Fluidmaster recommends the use of
Flush 'n' Sparkle™ Toilet Bowl Cleaning System (Models 8100, 8200
or 8300). It cleans the bowl without harming tank parts by isolating
the cleaner from the tank water, releasing it only to the bowl where
it is needed. Cartridges supply more than 1,000 flushes and are
a snap to replace.
INSTALLATION WITH FLUIDMASTER
8100 BOWL CLEANING SYSTEM
"IN"
®
"OUT"
Diagram 2
1. Shut off water supply to tank. Flush tank and sponge out remaining water.
Remove old fill valve assembly, tank ball, and wire guide unit (or flapper),
using pliers if necessary.
2. If you have a Fluidmaster bowl cleaning system, carefully disconnect
the tube from the fill valve. Do not disconnect the tube from the
dispenser (if you don't have a cleaning system, continue to Step 3).
3. Disassemble small parts – LOCK NUT, SHANK WASHER and ANGLE
ADAPTER for Valve installation (required); CONE WASHER and
COUPLING NUT for Water Supply Connection (optional–see Step 8).
4. Carefully remove CONE WASHER from center of SHANK WASHER. Place
SHANK WASHER on threaded shank of new VALVE. Place flat surface
against valve.
5. When installed, the critical level mark on the fill valve (identified by
a C.L. mark on the Fluidmaster Fill Valve) should be at least 1" above
the top of the overflow pipe. This is a plumbing code.
6. To adjust the height of the fill valve, twist the threaded shank in or out of
valve body. The height of the valve adjusts from 9 to 14 inches. On some
models, a clicking noise will be heard when adjusting the height. This
is normal.
7. Position valve inside tank. Push down on the valve shank (not the top)
while tightening lock nut. Hand tighten only. DO NOT OVERTIGHTEN or
tank may crack. Make sure float cup does not touch toilet tank walls, trip
mechanism or flush valve.
8. Before continuing, determine the type of water supply connection you
have from the chart on the left and use the appropriate assembly parts
required to properly reconnect the water supply. DO NOT use plumber's
putty to seal these fittings.
9. With correct washers in place (see Step 8), tighten coupling nut. Hand
tighten only. DO NOT OVERTIGHTEN. CAUTION: DO NOT USE CONE
WASHER WITH PLASTIC SUPPLY LINE.
10. Clean drain with a soft cloth. Snap adapter ring away from flapper. Align
FLAPPER over mounting ears located on base of overflow pipe. Center
flapper over drain opening. Snap to mounting ears by pushing down on
the rigid frame near mounting ears. Flapper should open and close
without binding.
11. ADAPTER RING FOR 1" OVERFLOW PIPES WITHOUT MOUNTING EARS.
If there are no mounting ears on base of overflow pipe, install Adapter
Ring: 1) Position adapter over top of overflow pipe and press down until it
expands and slips over the outside of the overflow pipe. If the adapter will
not slide down overflow pipe, remove spring, slip adapter around the pipe
and replace spring; 2) Slide adapter down until it contacts base of overflow
pipe. Position spring clip opposite the drain seat. NOTE: If overflow pipe is
brass, use steel wool or wet/dry sandpaper to remove excess scale from
pipe prior to installation. If overflow pipe is larger than 1", Model 555C
can be used.
12. If you have a Fluidmaster bowl cleaning system, re-attach tube ("IN") to
fill valve nipple (see Diagram 2). Be sure toilet tank flushing components
move freely (if you don't have a cleaning system, continue to Step 13).
13. Remove and discard overflow pipe cap if present. Attach one end of black
refill tube to angle adapter and the other end to nipple located near top of
valve. Attach angle adapter to overflow pipe. Trim refill tube as necessary
to prevent kinking. NOTE: Flow from refill tube must be positioned just
above the overflow pipe. Do not insert refill tube down into overflow pipe
below water level. This will siphon water down the overflow pipe, which
causes the valve to turn on and off as it tries to keep the tank full. If the
angle adapter cannot be used, you may need the Model 599 Refill
Clamp (not included).
14. Connect flapper chain/linkage to hole in tank lever arm that provides the
best lift. Chain should have slight slack when flapper is in closed position.
Replace lid. Check lift action for proper flush.
15. IMPORTANT: Always clear sand and rust from system. Make sure
water supply is shut off. Remove valve TOP by lifting arm and rotating
top and arm 1/8 turn counterclockwise, pressing down slightly on cap.
16. While holding a container over the uncapped VALVE to prevent splashing,
turn water supply on and off a few times. Leave water supply off.
17. Replace TOP by engaging lugs and rotating 1/8 turn clockwise. MAKE
CERTAIN TOP IS TURNED TO THE LOCKED POSITION. VALVE may not turn
on if top is not fully to the locked position.
18. Turn on water supply. Adjust water to desired level by squeezing water level
adjustment clip and moving FLOAT CUP up or down along stainless steel
link. Check for leaks, then check for proper flush.
TROUBLESHOOTING
IF FILL VALVE WON'T
TURN OFF,
• There may be debris at seal –
repeat Steps 15-17.
• The seal inside the valve top
may be damaged –replace
with genuine Fluidmaster
242 seal.
Go to our website at www.fluidmaster.com for more
solutions to toilet problems.
GUARANTEE: This Fluidmaster product is guaranteed to be free from defective
materials and workmanship for a period of one year. Units returned to
Fluidmaster, U.S.A., will be replaced without charge.
Always use quality Fluidmaster repair parts when maintaining your Fluidmaster
products. Fluidmaster shall not be responsible or liable for any damages
caused by products used in Fluidmaster valves that were not manufactured
by Fluidmaster, Inc.
30800 Rancho Viejo Road
San Juan Capistrano, CA 92675 U.S.A.
(949) 728-2000 (800) 631-2011 www.fluidmaster.com
®
Fights stains
WITHOUT
harming
tank parts.
CLEANING
POWER
More than 1,000 bleaching
flushes in every cartridge.
A crystal
clear bowl
after every
YEAR
flush.
W A R R A N T Y
MADE
Powerful
IN THE
®
USA
bleach injects
ONLY to
KEEP OUT OF REACH
the bowl.
OF CHILDREN
DANGER:
Unlike other
See back panel for additional
in-tank
precautionary statements
cleaners,
MANTENGA LEJOS DEL
ALCANCE DE LOS NIÑOS
WON'T
PELIGROSO:
corrode
Para otros medidas
de precaución, vea el
tank parts.
panel trasero.
Contents: 1 Dispenser & Mounting Bracket, 1 Cartridge, 2 Flexible Tubes, 1 Clip.
Cartridge content net wt. 1.20 oz (34.0 g)
IF FILL VALVE TURNS OFF AND
ON DURING PERIODS OF NON-USE,
• There may be a leak at the flapper.
• The tank ball or flapper is
misaligned – repeat Step 10.
• The seat is corroded or damaged –
replace with Flusher Fixer Kit,
Model 555C.
• The end of the refill tube is inserted
into overflow pipe below water
level in tank (See Step 13).
®

Publicidad

loading

Resumen de contenidos para Fluidmaster 400C

  • Página 1 5. When installed, the critical level mark on the fill valve (identified by WASHER SHANK a C.L. mark on the Fluidmaster Fill Valve) should be at least 1" above WASHER the top of the overflow pipe. This is a plumbing code.
  • Página 2 1 pulg (2.5cm), debe usarse el modelo 555C. 12. Si tiene el sistema limpiador de taza de Fluidmaster, fije el tubo (“IN”) a la boquilla de la válvula de llenado (vea el Diagrama 2). Compruebe que los compo- nentes que descargan el tanque del servicio puedan moverse libremente (si no tiene el sistema, continúe con la fig.