27

Operation of the door opener

Automatic opening / closing of the door:
The door opener can be operated using the following devices:
• Remote control: Press the button until the door starts to move.
• Wall switch (if this accessory is installed): Press the pushbutton until
the door starts to move.
Manual opening of the door (by hand):
If possible, the door must be closed completely. Weak or defective
springs can cause a rapid shutting down of the open door, which
can lead to property damage or serious personal injury.
RELEASE: Briefly pull the red handle down. Then open the door by hand.
Open close door without pulling the cable!
RECONNECT:
The lockout feature prevents the trolley from reconnecting automatically.
Push the green button on the trolley. With the next door movement the
system will reconnect.
Function sequence:
When operating the door opener by radio control or wall switch:
- closes the door when it is fully open,
- opens the door when it is fully closed,
- stops the door if it is opening or closing,
- the door moves in the opposite direction to the last completed move,
if it is partially open,
- drives back the door to the open door position, if it hits an obstruction
while closing,
- stops the door, if it encounters an obstacle during opening.
- Photocells (optional): By means of the photocells, a closing door
is lifted up or an open door is obstructed while closing, if a person
located in the door area interrupts the beam.
- THE MULTI-FUNCTION DOOR CONTROL (optional)
Press the push bar (1) to open or close the door. Press again to stop
the door.
Light feature
Press the Light button (2) to turn the opener light on or off. It will not
control the opener light when the door is in motion. If you turn it on and
then activate the opener, the light will remain on for 2-1/2 minutes.
Press again to turn it off sooner.
The operator light switches on in the following cases:
1. First turning on of the door opener (short)
2. Power interruption (short)
3. With each turning on of the door opener.
The light turns off automatically after 2 1/2 minutes.
28
Attach warning labels
29

Cleaning and maintenance

Before any maintenance, cleaning and related maintenance
work, the mains supply plug should be pulled out. Danger
from electric shock!
Maintenance of the door opener
A proper installation ensures the optimum performance of the door opener
with minimum maintenance. An additional lubrication is not required. Gross
dirt accumulation in the guide rail may impair the function and must be
removed.
30

Cleaning

Clean the drive head, wall switch and remote control with a soft, dry cloth.
Do not use liquids.
30.1

Maintenance

Check the system often, especially cables, springs and fasteners,
for signs of wear, damage or lack of balance. Do not use if repair
or adjustment work must be performed, because an error in the
system or an incorrectly balanced door may cause injury.
Once a month:
• Check automatic safety reverse again and reset if necessary.
• Operate door manually. If the door is unbalanced or stuck, please
contact the service centre.
• Check for complete opening and closing of the door.
Where appropriate, readjust limit switches and / or power.
Twice a year:
• Check the chain belt tension. For this, first disconnect the carriage
from the drive. If necessary, adjust belt tension.
• Lightly lubricate the guide rail with standard grease (lubrication).
Once a year (at the door):
• Lubricate door roller, bearings and joints. An additional lubrication of
the door opener is not required.
Do not grease the door rails!
Limit switch adjustment and force regulation:
These settings must be checked and undertaken properly during the
installation of the opener. Due to weathering, minor changes can occur
during operation of the opener that need to be addressed by a new setting.
This can particularly happen in the first year of operation.
Follow the instructions for setting travel limits and force (refer to section 23
and 33) carefully and re-check the automatic safety reverse after each
resetting.
(see fig. 28)
en 08/13