Descargar Imprimir esta página

NATURE & DECOUVERTES 15201640 Manual De Instrucciones página 8

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

SEASONAL AFFECTIVE DISORDER
Seasonal Affective Disorder (SAD) as known as winter depression, winter blues. It may cause people:
• Feel low, listless and fatigued
• Need for more sleep
• Have trouble concentrating
Symptoms occur during the same season each year. Most people with SAD start to have symptom in
winter and feel better in summer.
CONTRAINDICATION
The following conditions may be contraindication for use of this appliance:
• suffer(ed) from severe depression
• recent eye surgery or a diagnosed eye
condition which your doctor advised you to
avoid bright light
• on specific medication (i.e. certain antidepres-
sants, psychotropic drugs or malaria tablets);
Always consult your doctor before your start using this appliance if you have any of the above
conditions.
POSSIBLE SIDE EFFECTS
The following side effects you may experience:
• headaches
• eyestrain
Measures to avoid, minimize or alleviate these side effects:
• Increase the treatment distance
• Avoid using the appliance during the late
evening or before sleep
SAFETY AND PERFORMANCE STANDARDS
The "Energy Daylight" has been designed and manufactured to conform to the highest standards of
safety and performance including electromagnetic compatibility (EMC). The "Energy Daylight" conforms
to the applicable requirements of the following:
This appliance meets the requirement of Medical Device Directive
93/42/EEC for medical appliances.
• Less active than normal
• Lacking in energy
• have high blood pressure with vitreous
hemorrhage have no benefit;
• skin sensitive to light, such as systemic lupus
erythematosus
• sleeping problems
• nausea
• Stop using the appliance for a few days to
make the side effects disappear and then try
again.
14
The appliance is complied with the following emission and immunity standard, and test level:
Immunity Test standard
IEC 60601-1-2 Test Level
Electrostatic discharge (ESD)
IEC 61000-4-2
±  2kV, ±  4kV, ±  8kV, ±  15kV air
±  2kV, for power supply lines
Electrical fast transient/burst
±  1kV Signal input/ output
IEC 61000-4-4
100 kHz repetition frequency
±  0.5kV, ±  1kV differential lines
Surge IEC 61000-4-5
±  0.5kV, ±  1kV, ±  kV 2 common mode
Voltage dips, interruptions and variations
0 % UT; 0.5 cycle. At 0°, 45°, 90°, 135°, 180°, 225°, 270° and 315°.
on power supply input lines
0 % UT; 1 cycle and 70 % UT; 25/30 cycles; Single phase: at 0°.
IEC 61000-4-11
0 % UT; 250/300 cycle
Power frequency (50/60 Hz) magnetic
30 A/m - 50Hz/60Hz
field IEC 61000-4-8
3 V – 0,15 MHz – 80 MHz
Conducted RF IEC 61000-4-6
6 V in ISM and amateur radio bands between
0,15 MHz and 80 MHz – 80 % AM at 1 kHz
Radiated RF IEC 61000-4-3
10 V/m – 80 MHz – 2,7 GHz– 80 % AM at 1 kHz
Note: UT is the a.c. mains voltage prior to application of the test level.
Guidance and manufacturer's declaration - electromagnetic Immunity
Test Frequency
Band (MHz)
(MHz)
385
380 - 390
450
430 - 470
GMRS 460, FRS 460
710
Radiated RF
IEC61000-4-3
745
704 - 787
LTE Band 13, 17
(Test
780
specification for
ENCLOSURE PORT
810
IMMUNITY to RF
GSM 800/900, TETRA 800,
870
800 - 960
wireless
iDEN 820, CDMA 850, LTE Band 5
communications
930
equipment
1720
GSM 1800; CDMA 1900; GSM 1900;
1845
1 700 - 1 990
DECT; LTE Band 1, 3, 4, 25; UMTS
1970
Bluetooth, WLAN, 802.11 b/g/n,
2450
2 400 - 2 570
RFID 2450, LTE Band 7
5240
5500
5 100 - 5 800
WLAN 802.11 a/n
5785
Compliance Level
±  8kV contact
±  8kV contact
±  2kV, ±  4kV, ±  8kV, ±  15kV air
±  2kV, for power supply lines
Not applicable
100 kHz repetition frequency
±  0,5 kV, ±  1 kV differential lines
Not Applicable
0 % UT; 0.5 cycle. At 0°, 45°, 90°, 135°, 180°, 225°, 270° and 315°.
0 % UT; 1 cycle and 70 % UT; 25/30 cycles; Single phase: at 0°.
0 % UT; 250/300 cycle
30 A/m - 50Hz/60Hz
3 V – 0,15 MHz – 80 MHz
6 V in ISM and amateur radio bands between
0,15 MHz and 80 MHz – 80 % AM at 1 kHz
10 V/m – 80 MHz – 2,7 GHz– 80 % AM at 1 kHz
Modulation
Distance
Service
Modulation
(W)
Pulse modulation
TETRA 400
1,8
18 Hz
FM
± 5 kHz deviation
2
1 kHz sine
Pulse modulation
0,2
217 Hz
Pulse modulation
2
217 Hz
Pulse modulation
2
18 Hz
Pulse modulation
2
217 Hz
Pulse modulation
0,2
217 Hz
15
IMMUNITY TEST
(m)
LEVEL (V/m)
0.3
27
0.3
28
0.3
9
0.3
28
0.3
28
0.3
28
0.3
9

Publicidad