SPECIFICATION
Ambient temperature: 73.4°F ±9 (23°C ±5°C); Relative temperature: ≤75%
Accuracy: ±(% of reading + digits)
Maximum voltage between input terminal and earth ground: AC 600Vrms or
DC 600V
�
Fuse for mA µA input: F1 fuse, 0.5A H 1000V fast-fuse, (6.3×32)mm
�
Fuse for A input: F2 fuse, 11A H 1000V fast-fuse, (10×38)mm
Maximum display: Digital 3999 counts, updates 3/sec. Frequency: 9999 counts.
Analog pointer display: 41 segments, updates 30 times/sec.
Over-range indication: OL
Range: Automatic and Manual
Altitude: Operating 2000m
Operating temperature: 0°C ~ +40°C (32°F ~ 104°F)
Relative humidity: 0°C ~ +30°C (32°F ~ 86°F) ≤75%; +30°C ~ +40°C (86°F ~
104°F) ≤50%
Storage temperature: -10°C ~ +50°C (14°F ~ 122°F)
Electromagnetic compatibility: In an RF filed of 1V/m = Specified accuracy 5%
Battery: 9V, 6F22, NEDA1604 or equivalent
Low battery indication:
Dimensions (L x W x H): 182 mm x 90 mm x 45 mm (7.2 in x 3.5 in x 1.8 in)
Weight: Approx. 354g (0.78lb) with batteries installed
1. DC Voltage Measurement
Range
400.0mV
4.000V
40.00V
400.0V
600V
Input impedance: About 10M ;
(Input impedance is ≤3Ge except DC 400mV range)
Overload protection: ±600V
Resolution
0.1mV
1mV
10mV
100mV
1V
13
Accuracy
± (0.8%+3LSD)
± (0.8%+1LSD)
±(1.0%+3LSD)