In the "ECO" mode, the water heater produces its own algorithm to ensure
energy savings, respectively, to reduce your electricity bill, but to maintain
maximum comfort in use.
Principle of operation: after selecting one of the three Eco Smart modes, the
appliance will learn your habits and it will elaborate a weekly programme so
as to provide the necessary quantity of water in the respective time when you
need it and at the same time to save energy and thus to reduce your electricity
bill. This principle of operation requires a period of self-training which lasts a
week, and after that the Eco Smart mode begins to accumulate energy savings
without disturbing your comfort calculated on the basis of your studied habits.
The appliance continuously monitors your habits and continuously gets self-
trained.
In this mode it is impossible for you to intervene after it has been selected.
In case you often change your habits, the appliance will not be able to
elaborate an exact algorithm which to guarantee your comfort and to provide
you with hot water exactly when you need it. In this sense, if the operation of
the appliance in Eco Smart mode does not satisfy you and does not provide
you with the required comfort, and at the same time you want the appliance
to keep reducing your costs, by pressing the button
mode of operation – for higher level of comfort which again guarantees energy
saving, but to a lower extent. EC1 mode of operation is intended for users with
frequently changing habits for whom an exact schedule of weekly operation
would be difficult to establish.
To generate maximum energy savings, you can select the EC2 mode. This is a
SMART algorithm mode with overnight heating priority.
Note: When the power is turned off or off, the appliance keeps the settings for
up to 12 hours. You can restart the algorithm only by the On/Off button, and
the appliance will begin its self-training again.
"LOCK" function
By holding buttons
+
simultaneously, the control panel locks itself and
no commands may be given through it. If the panel is locked, the
is visualized on the display. If you press a certain symbol while the panel is
locked, all buttons light up but the appliance does not accept commands and
the
symbol flashes 3 times, prompting for unlocking. To unlock the panel
once again, you need to press and hold buttons
2 seconds.
"Vacation" mode
If you plan to be away from home for more than a day, you can enable the
Vacation mode, so that the electric water heater will "know" when you will be
back to provide you with hot water.
To turn the Vacation mode on, you need to press button
visualizes „00" days and the digits and symbol
number of days is not changed, the Vacation mode cannot be activated.
To introduce the number of days, use the
counter value is increased by one. If you press and hold the button, the counter
value increases automatically at a higher pace. The maximum number of days
you can set, is 90. The
symbol is still blinking. The other two parameters
are set as default settings: maximum number of showers at 18:00 on the last
vacation day.
To change the time, at which you will need the desired amount of hot water,
use the
button. To change the number of showers, use the
The parameters set are confirmed by pressing the
the Vacation mode. On the display the
constantly. The number of vacation days, the number of showers and the time
when hot water needs to be available, are visualized.
To exit the vacation mode without changes, you may either press
do not touch any button for a long time. The
To exit the Vacation mode, press any of the following buttons:
. If you press
, while the Vacation mode is activated, you enter the
programming mode and the number of days and the
again.
The number of days that you enter (the period of your absence) must
include the day on which you will be coming back home.
"BOOST" function (a one-time heating up to maximum temperature and
automatic return to the already selected mode of operation)
When the BOOST function is enabled the water heater will heat the water up to
max °C without changing the algorithm of operation of the respective mode of
operation. When the maximum temperature has been reached the appliance
automatically switches to the previously selected mode of operation. The
BOOST function is active with the following modes: Eco Smart, Vacation and
Weekly Programmer.
To enable the BOOST function, press continuously (for about 3 seconds) the
To deactivate BOOST, hold the
English
you can select EC1
+
simultaneously for
. The display
are flashing. If the "00"
button. If you touch it once, the
button.
button, thus activating
symbol stops blinking and is lit
symbol disappears.
,
symbol start blinking
button once again.
"RESTORE FACTORY SETTINGS" function
To enable this function, the appliance must be in Stand-by mode. You can
enable it by pressing and holding the
symbols on the display will be illuminated which will indicate that you have
restored the factory settings of the appliance.
"Shower" symbol
The Handset symbol
hot water that has already been heated and whether the amount set has been
reached in the different modes. The amount of water per shower is calculated
on the basis of the average European standards and it may not coincide with
your personal comfort.
When the "Handset" symbol is lit constantly, it means that the set amount of
hot water is reached. When the "Handset" symbol flashes, this indicates that the
appliance is in a warm-up mode. When more than one "showers" are not ready,
they flicker one after another continuously. Thus you obtain information about
the set amount of hot water and the amount reached at any given time.
Example:
Hot water for 2 showers is ready to use. The third shower is in the process of heating.
The final objective is to have hot water equivalent to 3 showers.
In the "Manual control" mode and the "BOOST" mode the screen visualizes a
timer counting the estimate time remaining until the set amount of hot water
is reached.
Problem log
Code of
error
Е01
Е02
symbol
Е03
Е04
Е05
Е06
Е07
Е08
Note: If you see the
contact an authorized service centre. You can find a list of them in the
warranty card.
PERIODIC MAINTENANCE
VIII.
In the conditions of normal use of the water heater, under the influence
of high temperature, limestone (the so-called lime scale) deposits on the
surface of the heating element. This worsens the heat exchange between the
heating element and the water. The temperature on the surface of the heating
element and around it increases. Specific noise can be heard – of boiling
water. The thermoregulator begins to switch on and off more frequently. A
"deceptive" activation of the thermal protection is possible. Due to these
facts, the manufacturer recommends preventive maintenance of your water
heater every two years by an authorized service centre or service facility, this
service remaining at the customer's expense. This preventive maintenance
should include cleaning and examination of the anode protector (for water
heaters with glass-ceramic coating), which has to be replaced with a new one,
if necessary.
To clean the appliance, use a damp cloth. Do not use abrasive or solvent-
containing detergents.
or, if you
The manufacturer does not bear responsibility for any consequences
arising from non-adherence to these instructions.
or
Instructions for protection of the environment
Old electric appliances contain valuable materials and must not be
disposed of with the domestic waste! Please contribute actively for
the protection of the resources and the environment and dispose
of the appliance in the buy-back centres organized for this purpose
(if such are available).
.
button for at least 10 seconds. All
provides you with information on the amount of
Name of error
Sensor 1 – The lower sensor is switched off
Sensor 1 - The lower sensor is in short circuit
Sensor 1 – The upper sensor is switched off
Sensor 1 - The upper sensor is in short circuit
Sensor 2 – The lower sensor is switched off
Sensor 2 - The upper sensor is in short circuit
Sensor 2 – The lower sensor is switched off
Sensor 2 - The upper sensor is in short circuit
symbol and any of the above listed errors, please