SET UP INSTRUCTIONS
Place dehumidifier in the upright position.
1. After transporting the dehumidifier to site, allow unit to
sit for 30 minutes before powering ON. This allows the
refrigerant system to stabilize and avoid damage.
Illustration of correct positioning for best performance
PROPER AIR FLOW IS ESSENTIAL: Do not place dehumidifier in a
position where the front Air Intake Grill or rear Air Outlet is blocked
This dehumidifier can attach 6.625 in. diameter air outlet ductwork.
To avoid airflow restrictions , Do not exceed a 16.5 foot length
ductwork.
Front Air
Intake Grill
KEEP CLEAR
18 in.
20 in.
28 in.
84 lbs.
300
5.5
75
145
27 ft.
25 ft.
Yes
Electrical & mechanical
Rotomolded PE
Yes
R410A
KEEP CLEAR
Air Outlet
Attach Ductwork
16.5 ft. Maximum
ENSURE PROPER DRAINAGE: This dehumidifier contains a
built-in pump that connects to draining hose in the back of
the unit. Ensure that external water does not create a slipping
hazard. To avoid pump damage or overuse, do not exceed a 10
foot vertical lift height between the pump and drain.
Rear Drain
Hose Outlet
Drain Hose
CONTROL PANEL
Digital Control Panel
• Read owners manual before
operation.
• Caution: Check machine and
filter daily.
•
ON/OFF: Press once to turn the unit ON or OFF.
•
PURGE: Press the "PURGE" key to empty water from
the pump reservoir. During normal operation the pump purges
automatically when the reservoir is full. Use "PURGE" before
moving the machine to avoid water spillage. The pump will
shut automatically after 40 seconds.
•
FUNCTION: Press the "FUNCTION" key, the screen
will display 'Humidity setting' 'Ambient humidity' 'Total running
hours' 'Ambient temperature'
•
REGULATE: Press "REGULATE" key to adjust
humidity, set total running hours/current job hours, or changing
F°/C°.
Long press "REGULATE" key 5 seconds. The coil sensor
temperature will display. The screen will return to display
ambient humidity after coil sensor temperature cursor flashes
for 3 seconds.
3
Instruction Manual
To Drain
10 ft. Maximum
Drain Height
• This unit needs a grounded
power supply.
• Do not block air intake or
outlet.
• Do not move or tilt the
machine when it is running.
Coil Sensor Temperature