For example as follows:
Centigrade 25
MAINTENANCE
Cleaning or Replacing Filter
NOTE: The working performance of the dehumidifier will be
greatly reduced if the filter is clogged. Check filter weekly.
Clean or replace filter if it gets clogged or damaged.
Ensure the dehumidifier is turned OFF and it is unplugged before
performing maintenance.
1. Remove filter as shown.
2. Vacuum any debris using vacuum hose and nozzle attachment.
3. Using warm water and mild detergent; wash filter and allow to dry.
4. Once dry, reinstall the filter.
• Water Pump Maintenance
NOTE: Water pump maintenance should be completed once unit
reaches 1000 hours of operation.
Ensure the dehumidifier is powered OFF and unplugged from the
outlet prior to any performed maintenance.
1. Remove Screws (4 pcs) to separate front housing.
Commercial Grade Dehumidifer
Fahrenheit 77
2. Remove water pipe to dismantle water pump.
3. Remove screw (1 pc) to remove water pump top cover.
4. Remove screws (4 pcs) to remove water pump bottom
cover and clean water pump.
5. Reinstall all equipment.
STORING THE UNIT
Follow the guidelines below when storing the machine.
1. Wind the power cord and drainage tube to the back of the
machine.
2. Stack the machines as shown if necessary.
NOTE: Do not stack more than two machines high.
1. Do not transport in stacked position.
5