Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The drain valve must only be used as intended. It is
not allowed to attach other objects to the drain
valve, for example a semi-pedestal.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
Technical Data
This mixer series-produced with EcoSmart
(flow limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 34)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions (see page 36)
Flow diagram (see page 37)
with EcoSmart
without EcoSmart
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
®
®
Assembly (see page 32)
English
Spare parts (see page 38)
XXX = Colors
000 = Chrome Plated
130 = Polished Bronze
140 = Brushed Bronze
330 = Polished Black Chrome
340 = Brushed Black Chrome
670 = Matt Black
700 = Matt White
990 = Polished Gold-Optic
Special accessories (order as an extra)
• special tool #58085000 (see page 32)
• Installation putty (see page 33)
Cleaning (see page 41)
Operation (see page 35)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
®
after a prolonged period of non-use.
• After periods of prolonged non-use, but at least
every third day, the fittings must be opened with the
handle in hot and cold position to prevent stagnation
in the connecting lines. Let the water run until the
®
water temperature is constant.
Test certificate (see page 48)