6
1.1
Speed controller / Régulateur de vitesse de
r o t a t i o n / Re g u l a d o r d e l n ú m e r o d e
revoluciones
1.2
Depth adjustment / Réglage en profondeur
/ Ajuste de la profundidad de fresado
1.3
Spindle stop / Dispositif darrêt de laxe /
Dispositivo de bloqueo del husillo
1.4
Pivoted turret stop / Butée tournante / Tope
de revólver
1.5
Collet nut / Lécrou de la pince de serrage /
Tuerca de la pinza
1.6
On/Off switch / Interrupteur marche/arrêt /
Interruptor de conexión/desconexión
Various dust created by power sanding,
sawing, grinding, drilling and other construction activities
contains chemicals known (to the State of California) to
cause cancer, birth defects or other reproductive harm. Some
examples of these chemicals are:
lead from lead-based paints,
crystalline silica from bricks and cement and other masonry
products, and
arsenic and chromium from chemically-treated lumber.
The risk from these exposures varies, depending on how
often you do this type of work.
To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment,
such as dust masks that are specially designed to filter out
microscopic particles.
Technical data
Wattage
Voltage
No load speed
Quick height adjustment
Fine height adjustment
Drive shaft connection of the spindle
Weight
Safety
acc. to IEC 745, UL 745, CSA C22.2 No. 745
1
Symbols
V
volts
A
amperes
Hz
hertz
W
watt
~
alternating current
n
no load speed
0
Class II Construction
rpm
revolutions or reciprocation per minute
2
Functional description
2.1
Intended use
The routers are designed for routing wood, plastics and similar
materials. Aluminium and plasterboard can also be processed
with corresponding cutters such as are listed in the Festool
catalogues. The user is liable for damages and injuries due to
incorrect usage.
2.2
Electrical connection and operation
The network voltage must conform to the voltage indicated
on the rating plate. A 16 A safety fuse (for 120 V) or a
corresponding protective circuit-breaker is required.
Under no circumstances should the electrical tool be used
when the power cable is damaged. A damaged cable must be
replaced immediately by an authorised Customer Service
Centre. Do not try to repair the damaged cable yourself. The
use of damaged power cables can lead to an electric shock.
2.3
Extension cable
If an extension cable is required, it must have a sufficient
cross-section so as to prevent an excessive drop in voltage
or overheating. An excessive drop in voltage reduces the
output and can lead to failure of the motor. The table beside
shows you the correct cable diameter as a function of the
cable length for the router OF 2000 E/1. Use only U.L. and
CSA listed extension cables. Never use two extension cables
together. Instead, use one long one.
Note: The lower the AWG number, the stronger the cable.
OF 2000 E/1
2 000 W
~ 120 V, 60 Hz
12 000 - 22 000 rpm
65 mm (2.56)
5 mm (0.20)
M 22 x 1
5.1 kg (11.2 lbs)