Closing and turning on the inverter
Closing the In-
verter and
Switching it on
5
6
7
16
CAUTION! An inadequate grounding conductor connection can cause serious in-
juries to persons and damage to (or loss of) property. The housing screws provide
an adequate grounding conductor connection for the housing ground and should
not be replaced under any circumstances by other screws that do not provide a
proper grounding conductor connection.
(1)
(2)
(5)
(7)
NOTE! The following three steps apply only if the AC and DC cables are routed
into the inverter from the side:
Insert AC and DC wires into the inverter.
Mount the conduits onto the inverter housing.
Connect the AC and DC cables to the inverter.
Replace the inverter housing from abo-
1
ve.
Tighten the four TX25 screws (1) - (4)
2
(3)
on the underside of the inverter.
(4)
Tightening torque = 2.5 Nm (1.84 ft. lb).
Tighten the two TX25 screws (5) and
3
(6) on the top of the inverter.
(6)
Tightening torque = 2.5 Nm (1.84 ft. lb).
Replace the rubber edge guards (7)
4
onto the left and right sides