Service Tasks; Leak Test; Calibrating The Oil Scales (For Asc 2300 G/Asc 3300 G Only) - Waeco AirCon Service Center ASC 1300 G Instrucciones De Uso

Estación de mantenimiento de aire acondicionado
Ocultar thumbs Ver también para AirCon Service Center ASC 1300 G:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

AirCon Service Center
9

Service tasks

9.1

Leak test

Check the AirCon Service Center once a year for leaks in accordance with
the applicable legal requirements. Use an electronic leak detector for this
purpose.
9.2
Calibrating the oil scales
(for ASC 2300 G/ASC 3300 G only)
I
NOTE
In order for the oil quantities and the UV additive to be measured
correctly, the zero point of the scales must be checked regularly and
reset if necessary.
Resetting is necessary:
 If the quantity in a container deviates by more than 10 ml from the
target value
 If the AirCon Service Center has been shaken, for example during
transport on bumpy roads
 Every four to six weeks
1. In the basic menu, use the cursor keys  or  to select "Other
selections":
2. Press ENTER to confirm.
3. Use the cursor keys  or  to select "Reset scales":
✓ You are then prompted to remove the containers from the scale:
EN
Short selection
Free selection
Other selections
ENTER-OK
Int. vessel filling
Flushing
Reset scales.
Service.
Remove the 3 Oil/UV
glasses from scales.
ENTER-OK STOP-EXIT
Service tasks
117

Publicidad

Tabla de contenido
loading

Tabla de contenido