Remark:
• Input impedance: 2MΩ.
• Frequency response: 40Hz~400Hz.
• Display effective value of sine wave (mean value response).
C.
DC Current
Range
2mA
20mA
200mA
20A
Remark:
• At 20A range: For continuous measurement ≤10 seconds and interval not less than 15
minutes.
• Measurement voltage drop: Full range at 200mV.
D.
AC Current
Range
20mA
200mA
20A
Remark:
• At 20 A range: For continuous measurement ≤10 seconds and interval not less than 15
minutes.
• Measurement voltage drop: Full range at 200mV.
• Frequency response: 40Hz~400Hz.
• Display effective value of sine wave (mean value response).
E.
Resistance Test
Range
200Ω
2kΩ
20kΩ
200kΩ
2MΩ
20MΩ
200MΩ
Remark:
• At 200MΩ range , test lead is in short circuit, and it is normal to display 1000 digits. During
measurement, subtract the 1000 digits from the reading.
Resolution
0.0001mA
0.001mA
0.01mA
0.001A
Resolution
0.001mA
0.01mA
0.001A
Resolution
0.1Ω
0.0001kΩ
0.001kΩ
0.01Ω
0.0001MΩ
0.001MΩ
0.01MΩ
±[5%(reading-1000)+10]
Accuracy
±(0.5%+5)
0.5A. 250V fast type fuse,
±(0.8%+5)
±(2%+10)
Accuracy
±(0.8%+10)
0.5A 250V fast type fuse,
±(1.2%+10)
±(2.5%+10)
Accuracy
±(0.5%+10)
±(0.3%+1)
±(0.5%+12)
Overload Protection
Ø5x20mm
Un-fused
Overload Protection
Ø5x20mm
Un-fused
Overload Protection
250V DC
or AC ms
33