CONTROL PANEL FEATURES
LED Data Center
1. Power Meter: Displays power output from generator
being used.
2. Output Ready Indicator LED (Green): Illuminates
when the generator is operating normally and indicates
the generator is producing electrical power at the
receptacles.
3. Overload Indicator LED (Red): Illuminates when the
generator is overloaded which means the generator's
wattage / amperage capacity has been exceeded by
connected electrical devices or by a power surge.
When this occurs, the Output Ready Indicator LED will
go off. The engine will continue to run, but the red
Overload Indicator LED will stay on, and power will no
longer be supplied to connected electrical devices.
To rest the generator:
Remove all applied loads and stop the engine. Review
for any faulty or shorted connections.
Start the generator and reconnect electrical devices
sequentially, allowing the generator to stabilize after
each device is connected. Make sure the total wattage
of connected electric devices are not exceeding
recommended rated output power.
1
2
3
Page 10
4 5
6
4. Oil Warning Indicator LED (Red): Illuminates when the
engine oil level falls below the safe operating level and
the generator will automatically shut off the engine. The
engine will not start until the proper amount of oil is in
the crankcase.
5. LED Multi-Meter: Displays voltage, frequency, and
total running time.
6. Fuel Meter: Displays fuel remaining in the fuel tank.
7. Select Button: Push this button to show the volage,
frequency or total running time in LED Multi-Meter.
7