Problem
The compressor does not start
immediately after pressing the
"FastFreeze", or after changing
the temperature.
Door is misaligned or interferes
with ventilation grill.
Door does not open easily.
The lamp does not work.
There is too much frost and
ice.
Water flows on the rear plate
of the refrigerator.
There is too much condensed
water on the rear wall of the re-
frigerator.
Water flows inside the refriger-
ator.
14
Possible cause
The compressor starts after a
period of time.
The appliance is not levelled.
You attempted to re-open the
door immediately after closing.
The lamp is in stand-by mode.
The lamp is defective.
The door is not closed correct-
ly.
The gasket is deformed or
dirty.
Food products are not wrap-
ped properly.
Temperature is set incorrectly.
Appliance is fully loaded and is
set to the lowest temperature.
Temperature set in the appli-
ance is too low and the ambi-
ent temperature is too high.
During the automatic defrost-
ing process, frost melts on the
rear plate.
Door was opened too fre-
quently.
Door was not closed com-
pletely.
Stored food was not wrapped.
Food products prevent the wa-
ter from flowing into the water
collector.
The water outlet is clogged.
Solution
This is normal, no error has oc-
curred.
Refer to installation instruc-
tions.
Wait a few seconds between
closing and re-opening of the
door.
Close and open the door.
Contact the nearest Author-
ized Service Centre.
Refer to "Closing the door"
section.
Refer to "Closing the door"
section.
Wrap the food products better.
Refer to "Control Panel" chap-
ter.
Set a higher temperature. Re-
fer to "Control Panel" chapter.
Set a higher temperature. Re-
fer to "Control Panel" chapter.
This is correct.
Open the door only when nec-
essary.
Make sure the door is closed
completely.
Wrap food in suitable packag-
ing before storing it in the ap-
pliance.
Make sure that food products
do not touch the rear plate.
Clean the water outlet.