SETTING THE FIRST REMOTE CONTROL
This operation can only be performed when the control unit is new, or after a total delete
of the memory.
During this step, power up only one control unit at time!
T1: First remote control to be set
+
A
B
T1
AUTOMATIC DISABLING OF THE FIRST
REMOTE CONTROL SETTING FUNCTION
Every time you connect the power supply to the control unit, you have 3 hours to
store the first remote control. After this time, the ability to store the remote control is
disabled. To reset the timer of the function you have to disconnect and reconnect the
power supply to the control unit.
SETTING THE ROTATION DIRECTION OF THE MOTOR
This operation is mandatory if the rotation direction of the motor does not match to the
UP and DOWN functions of the remote control as an exemple if giving UP command the
awning or blinds descend.
The proper motor direction must be set, if the motor is linked to a Wind sensor. In case of
a wind alarm, the motor will always perform the command associated to the UP button.
Setting the rotation direction using the SET button:
Interchanging the BROWN and BLACK motor wire on the terminals of the control unit,
will also reverse the rotation direction.
The control unit will keep this setting even after complete memory clearing.