Fault
Maschine does not function
Machine runs in a jerky manner
Machine wobbles
Table 3
If the fault in the machine is not eradicated
after following the procedure according to
the
above
table,
customer service must be informed and
commissioned with the execution of the
necessary repair work.
18
measures
prior
to
and
cleaning
machine
must
be
from
the
mains
by
or
servicing
the
exchanging
parts
or
manufacturer
or
their
Cause
•
the main plug (2, picture 1) is not
correctly inserted
•
the unit socket (5, Picture 1) is
not correctly inserted
SDP 430 only:
•
the thermo-protection has cut the
motor off.
•
soiled pad (1, picture 2)
•
Pad unevenly worn
•
Pad not fastened in centre of pad
holder
•
Pad holder or brush not installed
correctly
the
manufacturer's
2 _5.3
Cleaning the machine
Keep the bottom part of the machine in clean condition.
Clean or exchange brushes and floor pads.
2 _5.4
Pad care
After using, clean coarse soiling from the pads, which
can be used on both sides, and replace the pads within
good time in order to achieve good cleaning results.
2 _5.5
Daily examination
•
Check mains cable for damage.
2 _5.6
Annual maintenance
An electrically-driven machine must be checked
annually
according
to
international regulations
This examination should be carried out by
a service technician who has been trained
by the manufacturer!
Remedy
•
ensure correct seating
•
ensure correct seating
•
leave machine to cool down for 5 - 10
minutes approx.
•
beat pad out / if necessary, wash out
under water
•
insert new pad
•
remove pad from pad holder, fasten in
centre of pad holder
•
remove pad holder or brush and re-install
2 _5 Maintenance / care