9
(not provided)
Attach strain relief (not provided) to opposite side of junction box.
Note: The arrow (shown in the figure above) should align with the power
cord.
Insert the bare copper or green wire (ground) from the field supply wiring
into the ground connection "
the terminal block screw as shown.
Insert the white (neutral) wire to the "N" connection of the terminal block
and securely tighten the terminal block screw.
Insert the black (hot) wire to the "L" connection of the terminal block and
securely tighten the terminal block screw.
Tighten strain relief.
12
A
K
strain relief
" of the terminal block and securely tighten
ADVERTENCIA
ESTRICTAMENTE SIGA TODAS LAS INSTRUCCIONES DE ESTE MANUAL.
UTILICE SÓLO EL 14 O 12 DE ALAMBRE DE COBRE AWG CON UN GRADO
DE LA TEMPERATURA MÍNIMA DE 75 ° C (167 ° F).
COLOQUE TODOS LOS CABLES EN LA CAJA DE LA FUENTE DE ALIMEN-
TACIÓN Y LA INSTALACIÓN DE LA CUBIERTA. TORNILLOS DE CONEXIÓN
NO SON EXTRAIBLES.
1/2" (13 mm)
WIRE STRIP GAGE
CALIBRE DE POUR DÉNUDER
INDICADOR DE CABLE PELADO
WARNING
STRICTLY FOLLOW ALL INSTRUCTIONS IN THIS MANUAL.
USE ONLY 14 OR 12 AWG COPPER WIRE WITH A MIN. TEMP. RATING
OF 75°C (167°F).
PLACE ALL WIRING IN THE POWER SUPPLY BOX AND INSTALL COVER.
CONNECTION SCREWS ARE NOT REMOVABLE.
AVERTISSEMENT
OBSERVER TOUTES LES INSTRUCTIONS DE CE GUIDE.
UTILISER SEULEMENT DU FIL DE CUIVRE 14 OU 12 AWG AVEC UNE
COTE DE TEMPÉRATURE MINIMALE DE 75°C (167°F).
PLACER TOUS LES FILS DANS LA BOÌTE D'ALIMENTATION ET
REMETTRE LE COUVERCLE.
LES VIS DE CONNEXIONS NE SONT PAS AMOVIBLES.
view with cover installed
arrow