Troubleshooting
The following list will show you a series of error codes that may appear on the display of your hob. If the
problem persists, please contact your nearest authorised service centre.
ERROR CODE
F3/F4
F9/FA
E1/E2
E3
E5
PROBLEM
Induction coil temperature
sensor failure.
IGBT temperature sensor
failure.
Abnormal supply voltage.
High temperature of the
induction coil temperature
sensor.
High temperature of the IGBT
temperature sensor.
57
SOLUTION
Please contact the supplier.
Please contact the supplier.
Please check that the power supply is
normal.
Turn on after the power supply is normal.
Please contact the supplier.
Please restart when the hob has cooled
down.