Example 1: (factory setting)
1
No panel connected
2
No panel connected
5
Frequency: 50Hz
6
Search mode off
8 store setting: off→ on→ off
Store the settings (DS3-DS7) by changing switch ds-8 from off to on, and then back to off.
The LED's 'Inverter' and 'eco mode' and 'alarm' will flash four times to indicate
acceptance of the settings.
Example 2
1
No panel connected
2
No panel connected
5
Frequency: 60Hz
6
Search mode off
8 store setting: off→ on→ off
Example 3
1
Panel connected
2
Panel connected
5
Frequency: 60Hz
6
Search mode on
8 store setting: off→ on→ off