Install the earth system at least 10m (33ft) from any power supply earth peg,
underground telephone or power cable. Drive one 2m (6ft) earth stake into
the ground, until only 5cm (2") remain above the ground.
Note: Poor grounding can cause
interference on telephone lines, radios
and televisions. This can be recognised
by a clicking sound on telephones.
Step 3. Connect the fence
Connect the energizer's red (FENCE)
terminal to the fence using double
insulated cable. Remove 5cm (2") of
plastic coating from one end of the
cable. Bend the end of the wire to
form a loop. Unscrew the red (FENCE)
terminal and insert the loop of wire.
Screw the terminal closed, ensuring
the wire is firmly clamped. Attach
the other end of the cable to the
fence using a joint clamp.
Step 4. Plug the
energizer
into a power outlet
Check that the light on the front
of the energizer is flashing.
Green
To earth
Red
To fence
Light
11