VOLTAGE CHECKLIST
Yes
Unplug the energizer from
the power supply and remove
the fence wire from the
red (FENCE) terminal. Plug
energizer in again and check.
Is the voltage across the
terminals greater than 5000
volts?
Yes
Test the earth
system.
Is the ground
voltage more
than 200 volts?
Yes
Improve the earth
system: add
galvanised earth
stakes to the earth
system until the earth
voltage is 200 volts or
below.
12
Gallagher 3E4410 M350 M550 M650 Energizer User Manual
Is the energizer operating?
Energizer needs
to be serviced.
No
1. Check the electrical connections are
secure eg. from the fence to the red
(FENCE) terminal, from the ground system
to the green (GROUND) terminal, at gates
etc.
2. Check the voltage on the fence every
33m (100ft). Note if the voltage is
dropping. The closer to a fault, the lower
the voltage reading will be.
Become aware of things that cause
faults and always be on the lookout for:
stray pieces of wire on the fence, heavy
undergrowth, cracked or broken insulators,
broken wires etc.
Test the power
supply.
If the power
supply is OK then
No
the energizer
needs to be
serviced.
No

Publicidad

loading

Este manual también es adecuado para:

M550M650