„ DEFINITIONS
DANGER
WARNING
CAUTION
„ GENERAL SAFETY PRECAUTIONS
INTAKE AIR. Can contain carbon monoxide or other
contaminants. Will cause serious injury or death. Ingersoll
Rand air compressors are not designed, intended or approved
for breathing air. Compressed air should not be used for
breathing air applications unless treated in accordance with
all applicable codes and regulations.
Your air compressor unit is suitable for operating air tools, caulking
guns, grease guns, sandblasters, etc. Depending on your application,
the following accessories may be required:
• An air pressure regulator to adjust the air pressure entering the
tool or accessory.
• An air line filter for removal of moisture and oil vapor in
compressed air.
„ TRANSPORTING THE UNIT
The wheels and handle do not provide adequate clearance,
stability or support for pulling the unit up and down stairs or
steps. The unit must be lifted or pushed up a ramp. Do not use
the handle to lift the unit.
„ SELECTING A LOCATION
GENERAL - Select a clean, dry, well-lighted area with plenty of space
for proper cooling air flow and accessibility. Locate the unit on a
solid level surface at least 12 inches (30 cm) from walls. Ensure unit is
as level as possible.
TEMPERATURE - Ideal operating temperatures are between 32°F
and 104°F (0°C and 40°C). In lower temperatures, you must protect
safety/relief valves and drain valves from freezing.
80444425 Rev. D
WILL cause DEATH, SEVERE
INJURY or substantial property
damage.
CAN cause DEATH, SEVERE
INJURY or substantial property
damage.
WILL or CAN cause MINOR
INJURY or property damage.
DANGER
GENERAL INFORMATION
PREPARATION FOR USE
CAUTION
SAFETY
HAZARDOUS VOLTAGE - Can cause serious injury or death.
Disconnect power and bleed pressure from tank before
servicing. Lockout/Tagout machine. Compressor must be
connected to properly grounded circuit. See grounding
instructions in manual. Do not operate compressor in wet
conditions. Store indoors.
MOVING PARTS - Can cause serious injury. Do not operate with
guards removed. Machine may start automatically. Disconnect
power before servicing. Lockout/Tagout machine.
HOT SURFACES - Can cause serious injury. Do not touch. Allow
to cool before servicing. Do not touch hot compressor or
tubing.
HIGH PRESSURE AIR - Bypassing, modifying or removing
safety/relief valves can cause serious injury or death. Do not
bypass, modify or remove safety/relief valves. Do not direct air
stream at body. Rusted tanks can cause explosion and severe
injury or death. Drain tank daily or after each use. Drain valve
located at bottom of tank.
RISK OF BURSTING - Use only suitable air handling parts
acceptable for pressure of not less than the maximum
allowable working pressure of the machine.
• An in-line lubricator to prolong the life of air tools.
• Separate air transformers which combine the functions of air
regulation and/or moisture and dirt removal.
Contact your nearest authorized dealer or call 1-800-AIR-SERV for
more information on air tools and accessories for your application.
Never operate in temperatures below 20°F (-6.6°C) or above
125°F (51.0°C).
HUMID AREAS - In frequently humid areas, moisture may form in
the bare pump and produce sludge in the lubricant, causing running
parts to wear out prematurely. Excessive moisture is especially likely
to occur if the unit is located in an unheated area that is subject to
large temperature changes. Two signs of excessive humidity are
external condensation on the bare pump when it cools down and
a "milky" appearance in petroleum compressor lubricant. You may
be able to prevent moisture from forming in the bare pump by
increasing ventilation or operating for longer intervals.
NOISE CONSIDERATIONS - Consult local officials for information
regarding acceptable noise levels in your area. To reduce excessive
noise, use vibration mounts or intake silencers, relocate the unit or
construct total enclosures or baffle walls.
Contact your dealer for assistance.