2
Pool water is clear, but chlorine level measure is reduced to 0.
Q1
Activate the alarme A1, you have to adjust the production level on 10 (100%). Wait few minutes
and at the same time you have to check if "A1" doesn't appear: chlorine production is optimal
but this one is consumed very quickly.
Remedies :
o
o
o
o
o
Q2
What is maximum salt level?
Even if the salt level recommended exceeds 5 kg/m
repercussion on the device working.
What are treatment chemical products compatible with electrolysis?
Q3
All chlorine products (tablet, liquid etc...); hydrogen peroxide (active oxygen).
Forbidden products: PHMB, antiseaweed including copper and others metals.
MINISALT – PAPI004086MULTI – FR/EN/DE/IT/ESP/PT – Rev.05.16
You have to remain on 100 %;
You have to orientate slightly the backflow pipe to the pool bottom;
Increase the filtering time;
Proceed to filter cleaning;
Change regeants from your analysis kit, there are expired.
3
and reaches (7,8,9 Kg/m
3
), There is not