Descargar Imprimir esta página

LD Systems CURV 500 I AMP Manual De Usuario página 7

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 37
DELAY
Menu item for the configuring the channel delay (delay line). Press the rotary MENUdial to access the selection menu for device settings and turn
the dial to select the menu item DELAY (bright background). Now press the dial, and then turn it to select the channel on which you want to adjust
the delay. Press the dial again and set the desired value by turning the dial (anticlockwise = maximum delay, clockwise = fine tuning from 0 ms). The delay
is shown in milliseconds (ms), as well as in metres (m) or feet (ft) (see SETUP -> DELAY UNIT). Confirm your entry by pressing the dial. Repeat this procedure to
set the desired delay for the other channels. To return to the selection menu, turn the dial to select the menu item DELAY EXIT and confirm by pressing the
dial. Access the main display by turning the dial to select EXIT (light background) and confirm by pressing the dial. Following approximately 10 seconds of
no input, the main display will appear automatically.
ROUTING
Menu item for setting the input source for channels A to D. Press the MENUdial to access the device settings selection menu and turn the dial to
select the menu item ROUTING (light background). Now press the dial and then turn it to select the input source that you want to configure (Channel
A - D, each input source 1 - 4). Press the dial again, select the desired setting by rotating the dial (framed number = activated input source, number
without frame = deactivated input source) and confirm input by pressing the dial. To return to the selection menu, turn the dial to select the menu
item ROUTING EXIT and confirm by pressing the dial. Access the main display by turning the dial to select EXIT (light background) and confirm by
pressing the dial. Following approximately 10 seconds of no input, the main display will appear automatically.
EQUALIZER
Menu item for configuring the 10-band parametric equaliser for channels A to D. Press the MENUdial to access the device settings selection menu,
then turn the dial to select the menu item EQUALIZER (light background). Now press the dial and then turn it to select the channel that you want
to configure (channel A - D). Press the dial again, select the desired equalisation band 01 to 10 by rotating the dial, then confirm by pressing the
dial. Turn the dial to select FREQ (Frequency), Q (filter quality, low shelf LS and high Shelf HS) and GAIN and confirm by pressing the dial. Edit the
corresponding parameters as required and confirm by pressing the dial. To return to channel selection, turn the dial to select the menu item EXIT
EQ and confirm by pressing the dial. Repeat this procedure to set the desired EQ for the other channels. Access the main display by turning the dial
to select EXIT (light background) and confirm by pressing the dial. Following approximately 10 seconds of no input, the main display will appear
automatically.
7

Publicidad

loading

Este manual también es adecuado para:

Ldcurv500iamp