DEVICE CONFIGURATION (SETUP)
Menu item for editing device configuration, reading device firmware, resetting the device and managing global presets. Press the rotary MENUdial
to access the selection menu for device settings and turn the dial to select the menu item SETUP (bright background). Confirm by pressing the dial.
This will take you to the sub-menu with the following menu items (turn the MENU dial to select, then confirm by pressing MENU):
SETUP
FIRMWARE
The device firmware version is displayed in the top line of the display.
NAME
Configure individual amplifier name (8 digits):
Press the MENU dial -> Turn the MENU dial to select 1 to 8 -> Press MENU -> Rotate MENU to select letters, numbers,
or characters -> Press MENU -> To exit, rotate MENU dial clockwise to arrow icon -> Press MENU.
PIN
Activate automatic locking of controls to prevent accidental and unauthorised
operation (except MASTER VOLUME, if enabled):
ON / OFF / EDIT
Press MENU twice -> Rotate MENU to ON -> Press MENU -> To exit, rotate MENU to arrow symbol -> Press MENU
Deactivate automatic locking:
Enter PIN to unlock menu (4-digit PIN factory setting: 1234) -> Rotate MENU to SETUP -> Press MENU -> Rotate MENU to
PIN -> Press MENU twice -> Rotate MENU to OFF Press MENU -> To exit, rotate MENU to arrow symbol -> Press MENU
Set personal PIN:
Press MENU twice -> Rotate MENU to EDIT Press MENU -> Rotate MENU to select 0 - 9 for first digit -> Press MENU ->
Rotate MENU to select 0 -9 for second digit -> Press MENU etc. In the event of the PIN becoming lost, it can be reset to
the factory setting (1234) by using the PC software and USB interface (downloadable from the product page at WWW.
LD-SYSTEMS.COM).
DELAY UNIT
Configuring unit of measurement for channel delay METRES/FEET:
METRES / FEET
Press MENU -> Rotate MENU to select METERSor FEET -> Press MENU -> To exit, rotate MENU to arrow symbol
-> Press MENU
DELAY TEMP
Configuring distance calculation based on air temperature (sound speed is dependent upon air temperature):
Press MENU twice -> Rotate MENU to select temperature from 0°C to 40°C -> Press MENU -> To exit, rotate MENU to
arrow symbol -> Press MENU
CONNECT GND
Floating switching for disconnecting the signal ground from equipment grounding
YES / NO
(to prevent ground loops):
Press MENU twice -> Rotate MENU to YES for ground connection / NO for ground lift -> Press MENU -> To exit, rotate
MENU to arrow symbol -> Press MENU
FACTORY SETTING
Reset to factory settings (e.g. resetting PIN to 1234 and OFF):
NO / YES
Press MENU -> Rotate MENU to NO = do not reset device / YES = reset device -> press MENU
GLOBAL PRESET
Save all settings except amplifier name and PIN in global presets
(16 internal memory slots):
Press MENU -> Rotate MENU to SAVE PRESET -> Press MENU -> Rotate MENU to desired memory slot -> Press MENU ->
Configure preset name: Rotate MENU to select digit (9 digits) -> Press MENU -> Rotate MENU to select letter, number
or character -> Press MENU etc. -> Rotate MENU to YES -> Press MENU -> Rotate MENU to EXIT to go back -> Press MENU
-> To exit, rotate MENU to EXIT -> Press MENU
Loading a global preset from internal memory:
Press MENU -> Rotate MENU to LOAD PRESET -> Press MENU -> Rotate MENU to required preset -> Press MENU ->
Rotate MENU to YES -> Press MENU -> Rotate MENU to EXIT to go back -> Press MENU -> To exit, rotate MENU to EXIT
-> Press MENU
SCREENSAVER
Activate minimal display and reduced brightness (automatic activation after 5 minutes without input, display of channel
ON / OFF
and audio level):
Press MENU 2x -> rotate MENU to ON for activated screensaver / OFF for deactivated screensaver -> press MENU
-> to exit rotate MENU to arrow symbol -> press MENU
EXIT SETUP
To exit the setup-menu, rotate the MENU dial to EXIT SETUP and confirm by pressing MENU