Descargar Imprimir esta página

EINHELL GE-DP 18/25 LL Li Manual De Instrucciones Original página 19

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 89
To ensure that the battery pack provides long ser-
vice, you should take care to recharge it promptly.
You must recharge the battery pack when you
notice that the performance of the device drops.
Never allow the battery pack to become fully di-
scharged. This will cause it to develop a defect.
5.5 Battery capacity indicator (Fig. 7)
Press the button for the battery capacity indicator
(Item A). The battery capacity indicator (Item B)
shows the charge status of the battery using 3
LEDs.
All 3 LEDs are lit:
The battery is fully charged.
2 or 1 LED(s) are lit:
The battery has an adequate remaining charge.
1 LED fl ashes:
The battery is empty, recharge the battery.
All LEDs blink:
The battery temperature is too low. Remove the
battery from the equipment, keep it at room tem-
perature for one day. If the fault reoccurs, this me-
ans that the rechargeable battery has undergone
exhaustive discharge and is defective. Remove
the battery from the equipment. Never use or
charge a defective battery.
6. Operation
You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
Make sure that the equipment is set up se-
curely.
Check that the discharge line is fitted cor-
rectly.
Lower the pump into the well or shaft using a
securing cable, or hang it inside the rainwater
barrel.
The pump will start automatically after you
have pressed the pump setting switch (7).
Take care that the pump does not run dry.
To switch off the pump, press the pump mode
selector switch so that it is in "0" position.
Shallow suction mode (Fig. 8)
Turn the equipment clockwise and press it to
the bottom.
Anl_GE_DP_18_25_LL_Li_SPK13.indb 19
GB
In shallow suction mode, water can be su-
cked up down to a level of 1 mm.
Only clear water can be sucked up in shallow
suction mode.
Dirty water mode (Fig. 9)
Pull up the equipment by the handle and turn
it counter-clockwise as far as the stop.
Switching on the pump:
The pump has a pump setting switch (7) on the
battery box (6).
Switch position 0: Off
Switch position I: Pump setting 1 (ECO)
Switch position II: Pump setting 2 (BOOST)
Important!
Selecting pump setting 2 will increase the maxi-
mum delivery pressure and the maximum delivery
rate, but it will also reduce the maximum opera-
ting time of the battery as the result.
Dry-run safeguard:
The pump is equipped with a dry-run safeguard
and will switch off after approx. 20 seconds of no
medium being pumped. Switch off the pump with
the On/Off switch (7) or remove the battery in or-
der to reset the triggered dry-run safeguard. Then
the pump will be fully functional again. When you
start up the pump, check that the minimum level
of water is available.
7. Cleaning, maintenance and
ordering of spare parts
Danger!
Always pull out the battery pack before star-
ting any cleaning work.
For mobile applications, the equipment
should be cleaned with clear water after every
usage.
Use a water jet to remove any lint or fibrous
particles that may have become trapped in
the housing.
Remove sludge from the shaft bottom and
clean the shaft walls every 3 months.
7.1 Cleaning the paddle wheel
If a lot of deposits collect in the housing, the bot-
tom part of the equipment must be dismantled as
follows:
1. Disconnect the intake cage from the housing.
- 19 -
04.08.2022 10:52:34

Publicidad

loading

Este manual también es adecuado para:

Ge-dp 18/25 ll li-solo41.815.90