Descargar Imprimir esta página

Helo Roxx 60 Pure Instalación Y Manual De Uso página 35

Calentador de sauna eléctrico

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 78
Installation and User Manual HELO Roxx Pure
2. Heating the sauna
Before turning the sauna heater on, make sure the sauna room is suitable for taking a sauna bath. When heated
for the first time, the sauna heater may emit some odour. If you detect any odour while the sauna heater warms
up, disconnect the sauna heater briefly, and air the room. Then turn the sauna heater back on.
You should turn the sauna heater on roughly an hour before you plan to take a sauna bath, so that the stones
have time to heat up properly and the air warms up evenly in the sauna room.
If you encounter any problems, please contact the manufacturer's warranty service shop.
Pleasant, smooth sauna bath temperature is about 70 °C.
Do not put any objects on the sauna heater. Do not dry clothes on the sauna heater or anywhere in its
vicinity.
2.1 Recommended sauna room ventilation
5
4
Figure. 1 Rekommended sauna room ventilation
1. Sauna room 3. Electric sauna heater
2. Washroom
7. A ventilation valve can be installed here to be kept closed while the sauna is heated and during bathing.
Inlet vent can be positioned in the A zone. Make sure the incoming fresh air will not interfere with (i.e. cool down)
the sauna heater's thermostat near the ceiling.
The B zone serves as the incoming air zone, if the sauna room isn't fitted with forced ventilation. In this case, the
exhaust valve is installed min 1m higher than the inlet valve.
DO NOT ISTALL INLET VALVE WITHIN ZONE C, IF THE SAUNA HEATER'S CONTROL THERMOSTAT IS
LOCATED IN THE SAME ZONE.
2.2 Installing the sensor near a supply air vent
The sauna room air should be exchanged six times in an
hour. The diameter of the supply air pipe should be
between 50 and 100 mm.
A circular air supply vent (360°) must be
installed at least 1000 mm away from the sensor.
An air supply vent with a flow-directing panel
(180°) must be installed at least 500 mm away from
the sensor. Air flow must be directed away from the
sensor.
5
1
6
2
4. Exhaust valve
C
7
C
1000 mm
1
B
3
4
5. Exhaust flue or channel
6. Door to the sauna room
360°
180°
C
A
C
A
A
1
min
500 mm
B
3
1000 mm
Sensor
500 mm
Sensor
4

Publicidad

loading

Este manual también es adecuado para:

Roxx 90 pure1107-60-0405111107-90-040511