Descargar Imprimir esta página

Furrion F30-ATS Manual De Usuario página 3

Interruptor de transferencia automática de 30 amperios y 125 voltios

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLING YOUR F30-ATS:
There are 3 common installation configurations for the Furrion ATS series:
Configuration 1: Double power feed
This is the standard installation used between a shore power cord and generator.
SHORE POWER CORD
30Amp 120 VAC 3.75KW
FURRION PULL SMART PLUG FEATURED BELOW
Configuration 2: Triple power feed (same rating)
This configuration is used when a inverter is added to the system and requires automatic
switch over. See Diagram 2 which illustrates this configuration
Main Power Supply Wiring, with
30amp Sub Panel Inverter Feed.
DISTRIBUTION PANEL /
BRANCH CIRCUITS
SHORE POWER CORD
30Amp 125 VAC 3.75KW
FURRION PULL SMART PLUG FEATURED BELOW
CCD-0005572 Rev. 07.31.23
DISTRIBUTION PANEL /
BRANCH CIRCUITS
30Amp Generator/Power Cord
System Wiring
Output feed
F30-ATS
Transfer switch
Input 1
Input 2
Output feed
F30-ATS
Transfer switch
Input 1
Input 2
Output feed
F30-ATS
Transfer switch
Input 1
Input 2
EXAMPLE. 1
Typical RV Wiring Layout
GENERATOR
30Amp 125 VAC 3.75KW Generator
EXAMPLE. 2
POWER INVERTER
MAX 3000W
GENERATOR
30Amp 125 VAC 3.75KW Generator

Publicidad