Serial number
The CE labelling certifies that
the product complies with
the essential requirements of
Directive 93/42/EEC on medical
products.
Permissible operating tempe-
Operating
rature, humidity and ambient
pressure
3. Notes
Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to
other users and observe the information they contain.
Safety notes
Warning
• This infrared lamp is only intended for radiating the human body.
• Before use, ensure that all packaging materials are removed and that there is no visible damage to the
unit or accessories. When in doubt, do not use the unit and contact your dealer or the customer service
address provided.
• Always ensure that the appliance is on a secure and even surface.
• The lamp housing and the infrared lamp become very hot during operation. There is a risk of burning if
these are touched. Always let the lamp cool down first before touching it.
• Inflammable objects must be kept at a distance of at least 1.0 m from the infrared lamp. Do not hang the
appliance on the wall or from the ceiling.
• Connect the unit only to the mains voltage listed on the type plate.
• Do not dip the unit into water and do not use it in wet rooms.
• This device is not intended for use by persons (including children) with restricted physical, sensory or
mental capabilities and/or by persons lacking the required understanding of the equipment and how it is
used, unless they are supervised by a person who is responsible for their safety or they are given instruc-
tions on how to use the device.
• Do not use on babies and small children.
• Children should be supervised to ensure that they do not use the device as a toy.
• This device is not intended for use on changing units, cots or similar.
• Cleaning and user maintenace must not be performed by children unless supervised.
• Do not use it on persons sensitive to heat.
The sensitivity to heat can be reduced or increased in the following cases:
― diabetic patients
― persons with sleepiness, dementia or difficulties concentrating
― persons with illness-related skin changes or persons with scarred skin areas in the application area
― persons with allergies
― children and older persons
― after consuming medications or alcohol
• Do not operate the device if you are wearing an implant, particularly if it is located in the area of the body
to be treated. If you have any doubts, consult your doctor.
• If you are pregnant, do not operate the device near your abdomen, in order to prevent this area from over-
heating. If you have any doubts, consult your doctor.
• In case of acutely inflammatory processes, radiation should only be carried out after consulting a doctor.
• Always limit the period of use and check the reaction of the skin.
• Medications, cosmetics or food can lead to a over-sensitive or allergic reaction of the skin under certain
conditions. Radiation must be ended immediately in this case.
• An appropriate distance between the infrared lamp and the desired treatment area must be maintained
during treatment so that no skin irritation, such as tingling, itching, burning or too high heat sensitivity
occurs. Stop the treatment if this occurs. Alternatively, increase the radiation distance and/or reduce the
radiation duration.
• This device is not intended for radiation from above.
• The minimum distances described in these instructions for use must be adhered to.
The products must conform with
Russian standards
Permissible storage and transport tem-
Storage/Transport
perature, humidity and ambient pressure
Dispose of packaging in an environmen-
20
tally friendly manner
PAP
9