The equipment may be used only for the tasks it
is designed to handle. Any other use is deemed
to be a case of misuse. The user/operator and not
the manufacturer will be liable for any damage or
injuries of any kind resulting from such misuse.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
equipment is used in commercial, trade or indust-
rial businesses or for equivalent purposes.
4. Technical data
Speed n
.............................................8,500 min
0
Cutting circle .......................................... Ø 24 cm
Max. operating time ..................... approx. 40 min
Protection class ................................................III
L
sound power level ............................ 84.3 dB
WA
L
sound pressure level ......................... 64.3 dB
pA
K uncertainty ............................................ 2.97 dB
Interchangeable battery ..... 20 V d. c. / 1500 mAh
Vibration ..................................................5.8 m/s
K uncertainty .......................................... 2.3 m/s²
Weight ....................................................... 2.2 kg
Sound pressure level
at the operator's ear ............................... 78 dB(A)
K uncertainty ................................................. 3 dB
Power-X-Change
20 V, 1.5 Ah .............................. 5 lithium-ion cells
20 V, 3.0 Ah ............................ 10 lithium-ion cells
20 V, 4.0 Ah ............................ 10 lithium-ion cells
The lithium-ion batteries of the Power-X-Change
series are allowed to be charged only with the
Power-X charger.
Charging unit
Mains voltage ................... 200-250 V ~ 50-60 Hz
Output
Rated voltage ........................................ 21 V d. c.
Rated current ....................................... 3000 mA
Anl_GAT_E_20_Li_Kit_SPK7.indb 21
Anl_GAT_E_20_Li_Kit_SPK7.indb 21
GB
The machine noise might exceed 85 dB (A). The
operator will require noise protection measures
if this is the case. The noise is measured in ac-
cordance with EN ISO 11201:2010 and EN ISO
3744:2010. The value of the vibrations emitted by
the handle was determined in accordance with
EN 28662-1:1992.
Important.
The vibration value changes according to the
area of application of the electric equipment and
may exceed the specifi ed value in exceptional
circumstances.
Reduce noise generation and vibration to a
minimum!
-1
•
Use only equipment that is in perfect condi-
tion.
•
Maintain and clean the equipment regularly.
•
Adapt your way of working to the equipment.
•
Do not overload the equipment.
•
Have the equipment checked if necessary.
•
Switch off the equipment when not in use.
•
Wear gloves.
2
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
5. Before putting into operation
5.1 Fitting the safety hood (Fig. 3-4)
Push the guard hood (Fig. 1/Item 8) in the di-
rection of the arrow onto the motor housing as
shown in Fig. 3. Make sure that it latches in place
correctly! Make sure that the guard hood is fi tted
as in Fig. 4.
5.2 Fitting the blade head (Fig. 5 – 6)
Fit the blade head (Item 7) onto the mounting
shaft and fasten it with the screw (Item 14).
- 21 -
06.09.2016 09:33:36
06.09.2016 09:33:36