Klauke TEXTRON UNIPIPE UP 75 Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 25
Instruction Manual UP 75
______________________________________________________________________________
Instruction Manual
UP 75
For the universal battery pressing tool type UP 75
serial number ............................ ff..
Contents
1.
Introduction
2.
Labels
3.
Warranty
4.
Description of the electric hydraulic pressing unit
4.1
Components
4.2
Short description of the key features of the unit
4.3
The LED display
5.
Guide for intended use
5.1
Operation of the unit
5.2
Explanation of the application range
5.3
Fitting instructions
5.4
Maintenance instructions
5.5
Guide for the use of the battery and charger
5.6
Storage and transportation of the pressing unit
6.
Troubleshooting
7.
Decommissioning/Waste disposal
8.
Technical data
Symbols
Safety Instructions
Please strictly observe these instructions to avoid personal
injury and environmental damage
Operational Instructions
Please strictly observe these instructions in order to
prevent damage to the unit
1. Introduction
Before commissioning the pressing unit, please
read the instruction manual carefully
This tool is to be used only for its intended purpose, in accordance
with general health and safety regulations.
This instruction manual must accompany the tool for its entire life
span.
The operator must ensure
-
that the instruction manual is available to the user, and
-
that the user has read and understood the instruction manual
2. Labels
The type specification, details of origin and manufacturer's name
can be found on the type plate attached to the housing. On the
opposite side of the housing there is a label which provides
technical data. The serial number is on the hydraulic cylinder
between the housing and the pressing head. On the pressing head
there is a warning against the danger of crushing during operation.
3. Warranty
The warranty is for 12 months from the date of delivery, or 10,000
pressing cycles, provided that the unit has been operated correctly
and checked regularly as required.
4. Description of the electric hydraulic pressing unit
4.1 Components
The electric hydraulic pressing unit type UP75 is a hand-held unit
and consists of the following components.
Table 1 (see Picture 1)
Pos. Description
Function
1
Trigger
Operating switch to start the pressing
process
2
Retract button
Button to retract the piston in case of
error or emergency
3
Locking pin
Bolt to lock the pressing jaws
4
Pressing head
Receiving the pressing jaws
5
Housing
Ergonomically shaped plastic housing
with tank lid
6
LED display
Indicator for battery charge level and
other functions of the unit
7
Battery
Rechargeable NiCd battery
8
-
-
9
Hand guard
Protects the hand of the operator
10
Pressing jaws
Dies to press the fittings
11
Battery locking
Spring to hold the battery in place
spring
4.2. Short description of the unit's key features
The unit incorporates an automatic return function, which returns
the drive rolls to their starting position when the maximum
operating temperature is reached.
- The unit is equipped with a special brake which stops the forward
motion of the dies when the trigger (pos. 1) is released.
- The unit is equipped with a double piston pump which is
characterised by its rapid forward motion and slow pressing
motion.
- The pressing head (pos. 4) can be smoothly turned by 360° in
order to gain better access to difficult working areas (see pictures
3+4)
- The UP75 is controlled by a microprocessor which turns off the
motor when pressing is complete, displays service intervals and
the charge level of the battery (pos. 7), and carries out error
diagnosis.
4.3 The LED Display
The LED display works in conjunction with the electronic
controller of the unit, and provides information about the current
status of the battery and the unit. The display is activated in the
following cases.
-
When the battery is being inserted into the unit, the display
flashes a few times. This indicates that the electronic controller
is successfully performing its self-test.
-
If the display lights up continuously for around 20 seconds
after a pressing job, the battery is discharged and needs to be
recharged.
-
If, after a certain period of time, the display always flashes for
around 20 seconds at the end of a pressing job, the unit is due
for servicing, and should be sent to the factory as soon as
possible.
-
If an error occurs, the display will also flash at the end of a
pressing job. In this case, the flashing indicates the response of
the electronic controller. One possible reason for this is an
attempt to perform pressing with an unacceptably low battery.
If the display continues to flash even after the battery has been
changed, then there is either a different error or a service is due.
In this case the unit should be sent to the factory.
-
If the display lights up continuously for 20 seconds and flashes
afterwards, then a service is due and, at the same time, the
battery is discharged.
page 9